Mostrar el registro sencillo del ítem

Artículo

dc.creatorBallesteros Sánchez, Antonioes
dc.creatorGargallo Martínez, Beatrizes
dc.creatorGutiérrez Ortega, Ramónes
dc.creatorSánchez González, José Maríaes
dc.date.accessioned2024-06-06T11:35:46Z
dc.date.available2024-06-06T11:35:46Z
dc.date.issued2023
dc.identifier.citationBallesteros Sánchez, A., Gargallo Martínez, B., Gutiérrez Ortega, R. y Sánchez González, J.M. (2023). Intra-observer repeatability assessment of the S390L Firefly WDR slit lamp in patients with dry eye disease: Objective, automated and non-invasive measures. Eye & Contact Lens: Science and Clinical Practice, 49 (7), 283-291. https://doi.org/10.1097/ICL.0000000000001001.
dc.identifier.issn1542-233X (electrónico)es
dc.identifier.issn1542-2321 (impreso)es
dc.identifier.urihttps://hdl.handle.net/11441/159941
dc.description.abstractObjectives: To assess the intra-observer repeatability of automated, objective and non-invasive measures obtained with the S390L Firefly WDR slit lamp. Methods: This cross-sectional study included fifty eyes of patients with dry eye disease (DED) with a mean age of 55.06 ± 12.96 years. Three consecutively repeated measures of the following variables were obtained: first non-invasive break-up time (F-NIBUT), average non-invasive break-up time (A-NIBUT), tear meniscus height (TMH), tear meniscus area (TMA), nasal ciliary hyperemia (NCIH), temporal ciliary hyperemia (TCIH), nasal conjunctival hyperemia (NCOH), temporal conjunctival hyperemia (TCOH), upper loss area meibomian gland (U-LAMG), lower loss area meibomian gland (L-LAMG), upper meibomian gland dysfunction grade (U-MGD grade) and lower meibomian gland dysfunction grade (L-MGD grade). Intra-observer repeatability was estimated with coefficient of variation (CoV), intra-subject standard deviation (Sw) and Bland-Altman plots. Results: All variables showed no statistically significant differences in the repeated measures analysis except for L-MGD grade (P = 0.045). F-NIBUT and A-NIBUT obtained the highest CoV with an average value of 0.48 ± 0.41 [0.02 to 1.00] and 0.34 ± 0.25 [0.02 to 1.00], respectively. The remaining variables showed CoVs between 0.04 ± 0.11 [0.00 to 0.43] and 0.18 ± 0.16 [0.00 to 0.75]. A-NIBUT, TMA, NCOH and L-LAMG obtained a Sw of 2.78 s, 0.21 mm2, <0.001 and 4.11 %, respectively. Bland-Altman plots showed a high level of agreement between pairs of repeated measures. Conclusion: The S390L Firefly WDR slit lamp has moderate intra-observer repeatability for F-NIBUT and A-NIBUT, which suggests that they are tests with high variability. The remaining variables show satisfactory intra-observer repeatability.es
dc.formatapplication/pdfes
dc.format.extent26 p.es
dc.language.isoenges
dc.publisherLIPPINCOTT WILLIAMS & WILKINSes
dc.relation.ispartofEye & Contact Lens: Science and Clinical Practice, 49 (7), 283-291.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAutomatic objective measureses
dc.subjectDry eye diagnostic systemes
dc.subjectIntra-observer repeatabilityes
dc.subjectMeibomian gland dysfunctiones
dc.titleIntra-observer repeatability assessment of the S390L Firefly WDR slit lamp in patients with dry eye disease: Objective, automated and non-invasive measureses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/embargoedAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.date.embargoEndDate2024-07
dc.relation.publisherversionhttps://dx.doi.org/10.1097/ICL.0000000000001001es
dc.identifier.doi10.1097/ICL.0000000000001001es
dc.journaltitleEye & Contact Lens: Science and Clinical Practicees
dc.publication.volumen49es
dc.publication.issue7es
dc.publication.initialPage283es
dc.publication.endPage291es

FicherosTamañoFormatoVerDescripción
Intraobserver Repeatability_Sánchez ...12.13MbIcon   [PDF] Este documento no está disponible a texto completo   hasta el  2024-07 . Para más información póngase en contacto con idus@us.es.Versión Aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional