Mostrar el registro sencillo del ítem

Artículo

dc.creatorChi, Doris A.es
dc.creatorMoreno-Rangel, Davides
dc.creatorNavarro Casas, Jaimees
dc.date.accessioned2024-06-05T10:39:31Z
dc.date.available2024-06-05T10:39:31Z
dc.date.issued2017-11-15
dc.identifier.citationChi, D.A., Moreno-Rangel, D. y Navarro Casas, J. (2017). Design optimisation of perforated solar façades in order to balance daylighting with thermal performance. Building and Environment, 125, 383-400. https://doi.org/10.1016/j.buildenv.2017.09.007.
dc.identifier.issn0360-1323es
dc.identifier.issn1873-684Xes
dc.identifier.urihttps://hdl.handle.net/11441/159736
dc.description.abstractOn fully-glazed building façades perforated solar screens (PSS) are often used as an outer skin in order to reduce energy consumption and to solve issues such as visual appearance. However, not only must PSS control solar radiation but they must also provide adequate daylight levels, thus requiring a balanced solution. Currently, daylighting simulation software enables us to perform efficient daylight analysis of spaces with PSS. Notwithstanding this, current energy simulation software such as EnergyPlus cannot deal well with such geometry directly, making the thermal evaluation of PSS an infeasible task. This paper presents a methodology for achieving an integrated analysis of daylighting and energy consumption of spaces with PSS during the design stage. Such methodology provides daylight analysis through DIVA, and thermal analysis through EnergyPlus via DIVA/Grasshopper/Archsim. The aim is to optimise the dual performance of a balanced PSS solution through controlling its perforation percentage, matrix and shape, by using the orthogonal arrays (DOA) statistical method. DOA method is efficient in reducing the number of simulations derived from the combination of the aforementioned variables, and in identifying the optimal PSS configuration. In comparison to a non-optimised façade located in Seville, Spain, the predicted optimal PSS achieved a 50% increase in the actual daylit area and a 55% reduction in the total energy demand.es
dc.formatapplication/pdfes
dc.format.extent32 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofBuilding and Environment, 125, 383-400.
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectDaylight availabilityes
dc.subjectEnergy consumptiones
dc.subjectOptimal designes
dc.subjectOrthogonal arrayses
dc.subjectPerforated solar screenses
dc.subjectSimulation toolses
dc.titleDesign optimisation of perforated solar façades in order to balance daylighting with thermal performancees
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas I (ETSA)es
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/abs/pii/S0360132317304146?via%3Dihubes
dc.identifier.doi10.1016/j.buildenv.2017.09.007es
dc.contributor.groupUniversidad de Sevilla. TEP130: Arquitectura, Patrimonio y Sostenibilidad: Acústica, Iluminación, Óptica y Energíaes
dc.journaltitleBuilding and Environmentes
dc.publication.volumen125es
dc.publication.initialPage383es
dc.publication.endPage400es
dc.contributor.funderConsejo Nacional de Ciencia y Tecnología (CONACYT). Méxicoes
dc.contributor.funderUniversidad de Sevillaes

FicherosTamañoFormatoVerDescripción
Design optimisation of perforated ...2.567MbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución-NoComercial-CompartirIgual 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución-NoComercial-CompartirIgual 4.0 Internacional