dc.creator | Luque Siles, Carmen | es |
dc.creator | Gallego Izquierdo, Tomas | es |
dc.creator | Jiménez Rejano, José Jesús | es |
dc.creator | Granados de la Orden, Susana | es |
dc.creator | Plaza Manzano, Gustavo | es |
dc.creator | López Illescas Ruiz, Africa | es |
dc.creator | Ferragut Garcías, Alejandro | es |
dc.creator | Romero-Franco, Natalia | es |
dc.creator | Martín Casas, Patricia | es |
dc.creator | Pecos Martín, Daniel | es |
dc.date.accessioned | 2024-05-31T18:11:46Z | |
dc.date.available | 2024-05-31T18:11:46Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | Luque Siles, C., Gallego Izquierdo, T., Jiménez Rejano, J.J., Granados de la Orden, S., Plaza Manzano, G., López Illescas Ruiz, A.,...,Pecos Martín, D. (2016). Reliability and minimal detectable change of three functional tests: Forward-lunge, step-up-over and sit-to-stand. Journal of Physical Therapy Science, 28 (12), 3384-3389. https://doi.org/10.1589/jpts.28.3384. | |
dc.identifier.issn | 0915-5287 | es |
dc.identifier.uri | https://hdl.handle.net/11441/159571 | |
dc.description.abstract | [Purpose] To examine the intrasession and intersession reliability and the absolute reliability of three
functional dynamic tests—forward-lunge, step-up-over and sit-to-stand tests—using computerized dynamic pos
turography. [Subjects and Methods] An intra-test and test-retest, repeated measure study was designed. Forty-five
healthy subjects twice carried out the forward-lunge test, step-up-over test, and sit-to-stand test on two days, one
week apart. The intrasession and intersession reliabilities as judged by the intraclass correlation coefficient (ICC)
and the minimal detectable change of the three functional tests were calculated. [Results] Excellent to very good
intrasession reliability of the forward-lunge test (ICC range of 0.9–0.8) was found. Very good to good intrasession
reliability of the step-up-over test (ICC range of 0.9–0.5) was found and very good intrasession reliability of the
sit-to-stand test (ICC range of 0.8–0.7) was found. The minimal detectable change at the 95% confidence level of
most of the measures was lower than 30%. [Conclusion] The forward-lunge, step-up-over and sit-to-stand tests are
reliable measurement tools. | es |
dc.format | application/pdf | es |
dc.format.extent | 6 p. | es |
dc.language.iso | eng | es |
dc.publisher | I P E C Inc. | es |
dc.relation.ispartof | Journal of Physical Therapy Science, 28 (12), 3384-3389. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Postural balance | es |
dc.subject | Reproducibility | es |
dc.subject | Activities of daily living | es |
dc.title | Reliability and minimal detectable change of three functional tests: Forward-lunge, step-up-over and sit-to-stand | es |
dc.type | info:eu-repo/semantics/article | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Fisioterapia | es |
dc.relation.publisherversion | https://www.jstage.jst.go.jp/article/jpts/28/12/28_jpts-2016-474/_article | es |
dc.identifier.doi | 10.1589/jpts.28.3384 | es |
dc.contributor.group | Universidad de Sevilla. CTS305: Área de Fisioterapia. | es |
dc.journaltitle | Journal of Physical Therapy Science | es |
dc.publication.volumen | 28 | es |
dc.publication.issue | 12 | es |
dc.publication.initialPage | 3384 | es |
dc.publication.endPage | 3389 | es |