dc.identifier.citationCarrión Camacho, M.R., Molina Doñoro, J.M. y González López, J.R. (2020). Risk factors concerning complications following permanent pacemaker implantation for patients on antithrombotic therapy: A cohort study. Journal of Investigative Medicine, 68 (4), 828-837. https://doi.org/10.1136/jim-2019-00123.
dc.identifier.issn1081-5589es
dc.identifier.issn1708-8267es
dc.identifier.urihttps://hdl.handle.net/11441/159519
dc.description.abstractThe objective of this study was to identify the complications and associated factors presented by patients after pacemaker implantation, according to a regimen of antithrombotic therapy or without it. This is an analytical observational study on a prospective cohort of 310 consecutive patients with a permanent pacemaker implanted, included from January 1 to December 31, 2014 from 1 single center. The follow-up was conducted on 310 patients for 6 months. 239 patients (77%) received antithrombotic therapy at the time of the pacemaker implantation. 20.8% of complications are presented in patients without anticoagulant therapy, 80.8% of them being minor ones. In the case of patients with anticoagulant therapy, 30.3% of the complications are major ones. Factors associated with major complications were contusion (OR 2; 95% CI 1 to 3.8; p=0.049), and minor complications, arm immobilization >24 hours (p=<0.001) and contusion (p=0.002). This study found an increase in the overall risk and complications that can occur when implanting a permanent pacemaker in patients with antithrombotic therapy based on the time of immobilization and contusions after the implantation.es
dc.formatapplication/pdfes
dc.format.extent20 p.es
dc.language.isoenges
dc.publisherSAGE PUBLICATIONS INCes
dc.relation.ispartofJournal of Investigative Medicine, 68 (4), 828-837.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectPacemakeres
dc.subjectartificiales
dc.subjectPerioperative Carees
dc.subjectAnticoagulant drugses
dc.subjectAntithrombotic therapyes
dc.subjectPostoperative Complicationses
dc.subjectPatient Safetyes
dc.titleRisk factors concerning complications following permanent pacemaker implantation for patients on antithrombotic therapy: A cohort studyes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Enfermeríaes
dc.relation.publisherversionhttps://journals.sagepub.com/doi/10.1136/jim-2019-001238es
dc.identifier.doi10.1136/jim-2019-00123es
dc.journaltitleJournal of Investigative Medicinees
dc.publication.volumen68es
dc.publication.issue4es
dc.publication.initialPage828es
dc.publication.endPage837es

FicherosTamañoFormatoVerDescripción
Risk factors concerning compli ...556.3KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional