Mostrar el registro sencillo del ítem

Artículo

dc.creatorParís García, Federicoes
dc.creatorBarroso Caro, Albertoes
dc.creatorParís Carballo, Federicoes
dc.date.accessioned2024-03-01T12:08:20Z
dc.date.available2024-03-01T12:08:20Z
dc.date.issued2018-06
dc.identifier.citationParís-García, F., Barroso, A. y París, F. (2018). A study of the reproducibility and reliability of the musculo-articular stiffness of the ankle joint. Journal of the Mechanical Behavior of Biomedical Materials, 82, 145-153. https://doi.org/10.1016/j.jmbbm.2018.03.017.
dc.identifier.issn1751-6161es
dc.identifier.issn1878-0180es
dc.identifier.urihttps://hdl.handle.net/11441/155745
dc.description.abstractThe objective of this work was to evaluate the reproducibility, reliability and usefulness of the musculo-articular stiffness (MAS) of the ankle joint, measuring it by the free vibration technique. Seventeen (nine males and eight females) healthy university students were included in the study. Force (f), MAS (k) and unitary MAS (ku) (defined as the ratio between the value of stiffness k obtained in the test (absolute terms) and the value of force (f)) were obtained. A test-retest protocol was designed and performed on the same day to determine the short-term reproducibility of f, k and ku. Short-term reproducibility of k and ku on 1 day in absolute terms (< 7% Coefficient of Variation (CV)) and relative reproducibility (Intraclass Correlation Coefficient (ICC) and Pearson ≥ 0.97) for both feet were obtained. The reliability of k and ku in absolute terms (< 9% CV) and in relative terms (ICC and Pearson ≥0.93) based on repeating the protocol for 1 week was analysed for both feet. To analyse the usefulness, the Effect Size (ES) ratio = “Trivial” for all variables (for 1 day and 1 week) and the Smallest Worthwhile Change (SWC) ratio (Typical Error (TE)< SWC) = “GOOD” for k and ku (1 day and 1 week) were considered. The Minimal Difference needed to be considered “real” (MD) for ku ≅ 3.5% (1 day); ku≅ 8.5% (1 week) (p < 0.05) was obtained. The statistical analysis carried out displayed the high reproducibility, reliability and usefulness of the MAS test, which was more consistent with ku than k. Therefore, the unitary stiffness (ku) proven to be representative of the mechanical response of the ankle joint obtained by free vibration techniques, which allows comparison between different subjects.es
dc.formatapplication/pdfes
dc.format.extent9 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofJournal of the Mechanical Behavior of Biomedical Materials, 82, 145-153.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectStiffnesses
dc.subjectFunctional responsees
dc.subjectFree vibration techniquees
dc.subjectReliabilityes
dc.titleA study of the reproducibility and reliability of the musculo-articular stiffness of the ankle jointes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Mecánica de Medios Continuos y Teoría de Estructurases
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S1751616118303254es
dc.identifier.doi10.1016/j.jmbbm.2018.03.017es
dc.contributor.groupUniversidad de Sevilla. TEP131: Grupo de Elasticidad y Resistencia de Materialeses
dc.journaltitleJournal of the Mechanical Behavior of Biomedical Materialses
dc.publication.volumen82es
dc.publication.initialPage145es
dc.publication.endPage153es

FicherosTamañoFormatoVerDescripción
JMBBM_2018_Paris_Barroso_ A ...1.488MbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional