Mostrar el registro sencillo del ítem

Artículo

dc.creatorRíos-Santos, J.V.es
dc.creatorMenjívar Galán, Ana Maríaes
dc.creatorHerrero-Climent, Marianoes
dc.creatorRíos Carrasco, Blancaes
dc.creatorFernández Palacín, Anaes
dc.creatorPérez, Románes
dc.date.accessioned2024-02-02T14:48:49Z
dc.date.available2024-02-02T14:48:49Z
dc.date.issued2018
dc.identifier.citationRíos-Santos, J.V., Menjívar-Galán, A.M., Herrero-Climent, M., Ríos Carrasco, B., Fernández Palacín, A. y Pérez, R. (2018). Unravelling the effect of macro and microscopic design of dental implants on osseointegration: a randomised clinical study in minipigs. Journal of Materials Science: Materials in Medicine, 29, 99. https://doi.org/10.1007/s10856-018-6101-1.
dc.identifier.issn1573-4838es
dc.identifier.urihttps://hdl.handle.net/11441/154502
dc.description.abstractSeveral dental implants are commercially available and new prototype design are constantly being fabricated. Nevertheless, it is still unclear what parameters of the design affect most the osseointegration of dental implants. The purpose of this study is to assess the effects of the microscopic and macroscopic design of dental implants in the osseointegration by comparing three macroscopic designs (Straumann tissue level (STD), essential cone (ECD) and prototype design (PD)) and six surface treatments. A total of 96 implants were placed in 12 minipigs. The implant stability quotient (ISQ), was assessed at the time of implantation, as well as at 2, 4 and 8 weeks. Histomorphometric and statistical analyses were conducted at the different sacrifice times, being 2, 4 and 8 weeks, to analyse the bone to implant contact (BIC), the bone area density (BAT) and the density of bone outside the thread region (ROI). The macroscopic design results showed higher ISQ values for the ECD, whereas the histomorphometric analysis showed higher ossoeintegration values for the STD. Regarding the microscopic design, both Sandblasted plus acid etching (hydrochloric/sulphuric acid) in a nitrogen atmosphere (SLActive) and Shot-blasted or bombarded with alumina particles and posterior alkaline immersion and thermal treatment (ContacTi) showed superior results in terms of osseointegration and reduced the osseointegration times from 8 weeks to 4 weeks compared to the other analysed surfaces. In conclusion, each of the macroscopic and microscopic designs need to be taken into account when designing novel dental implants to enhance the osseointegration process.es
dc.formatapplication/pdfes
dc.format.extent11 p.es
dc.language.isoenges
dc.publisherSpringeres
dc.relation.ispartofJournal of Materials Science: Materials in Medicine, 29, 99.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectDental implantses
dc.subjectImplant surfaceses
dc.subjectMacrodesing and microdesinges
dc.subjectOsseointegrationes
dc.subjectImplant desinges
dc.titleUnravelling the effect of macro and microscopic design of dental implants on osseointegration: a randomised clinical study in minipigses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Medicina Preventiva y Salud Públicaes
dc.relation.publisherversionhttps://link.springer.com/article/10.1007/s10856-018-6101-1es
dc.identifier.doi10.1007/s10856-018-6101-1es
dc.journaltitleJournal of Materials Science: Materials in Medicinees
dc.publication.volumen29es
dc.publication.initialPage99es

FicherosTamañoFormatoVerDescripción
Unraveling...pdf701.9KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional