dc.identifier.citationGarcía Mejido, J.A., Martín-Martínez, A., González-Diaz, E., Fernández-Fernández, C., Ortega, I., Medina, M.,...,Sáinz Bueno, J.A. (2019). Malmström vacuum or Kielland forceps: which causes more damage to pelvic floor?. Ultrasound in Obstetrics and Gynecology, 55 (2), 257-263. https://doi.org/10.1002/uog.20404.
dc.identifier.issn0960-7692es
dc.identifier.issn1469-0705es
dc.identifier.urihttps://hdl.handle.net/11441/154002
dc.description.abstractObjective To determine whether differences exist in the rate of levator ani muscle (LAM) avulsion between women who had undergone either Malmström vacuum delivery (MVD) or Kielland forceps delivery (KFD), allowing for potential confounding factors. Methods This was a prospective observational study of nulliparous women undergoing instrumental delivery using Malmström vacuum extractor or Kielland forceps, at two hospital centers in Spain. Fetal head position (anterior, posterior or transverse) and fetal head station (low or mid) were assessed by ultrasound and digital examination, respectively. Avulsion was defined on tomographic ultrasound imaging as an abnormal insertion of the LAM in the three central slices from the plane of minimal hiatal dimensions. Results In total, 414 patients were included in the study (212 MVD and 202 KFD). We observed a higher rate of LAM avulsion in the KFD group (KFD 49.5% vs MVD 32.5%; P = 0.001). When the results were evaluated according to fetal head position and station, we observed no differences in LAM avulsion. The crude odds ratio (OR) for the difference in avulsion between women in the KFD and MVD groups was 2.03 (95% CI, 1.36–3.03). However, when adjusted for duration of second stage of labor, fetal head circumference and fetal head station, the OR was no longer statistically significant (OR, 2.14 (95% CI, 0.95–4.85); P = 0.068). Conclusion When potential confounding factors are taken into account, the rate of LAM avulsion does not differ between women according to whether they have undergone KFD or MVD.es
dc.formatapplication/pdfes
dc.format.extent7 p.es
dc.language.isoenges
dc.publisherWileyes
dc.relation.ispartofUltrasound in Obstetrics and Gynecology, 55 (2), 257-263.
dc.subject3D transperineal ultrasoundes
dc.subjectForceps deliveryes
dc.subjectlevator ani musclees
dc.subjectVacuum deliveryes
dc.titleMalmström vacuum or Kielland forceps: which causes more damage to pelvic floor?es
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Cirugíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Medicina Preventiva y Salud Públicaes
dc.relation.publisherversionhttps://obgyn.onlinelibrary.wiley.com/doi/10.1002/uog.20404es
dc.identifier.doi10.1002/uog.20404es
dc.journaltitleUltrasound in Obstetrics and Gynecologyes
dc.publication.volumen55es
dc.publication.issue2es
dc.publication.initialPage257es
dc.publication.endPage263es

FicherosTamañoFormatoVerDescripción
Malmström vacuum or Kielland ...1.970MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.