dc.coverage.spatialInternacionales
dc.coverage.temporal1998-2021es
dc.creatorTejero González, Anaes
dc.creatorFranco Salas, Antonioes
dc.date.accessioned2024-01-24T10:21:19Z
dc.date.available2024-01-24T10:21:19Z
dc.date.created2021-05-21
dc.date.issued2024-01-24
dc.identifier.citationTejero González, A., y Franco Salas, A. (2024). Optimal_operation_evaporative_cooling_pads_review_[dataset]. idUS (Depósito de Investigación de la Universidad de Sevilla). https://doi.org/10.12795/11441/153904.
dc.identifier.urihttps://hdl.handle.net/11441/153904
dc.description.abstractDataset acquired for the study published in the paper: “Optimal operation of evaporative cooling pads: A review”. The paper conducts a critical review on the existing experimental and theoretical research on commercial and alternative wetted media, identifies the gaps in the literature, proposes uniform nomenclature and methodologies, and provides a critical view on the optimal operating conditions from wetted-surface evaporative coolers.es
dc.description.tableofcontentsDataset whose contents are structured in an Excel table, where each row contains the reference of the paper cited (first author; year) followed by whether it is an experimental work or a simulation/model, type of evaporator panel used, the operating parameters studied as well as the factors analysed that influence these operating parameters and, finally, the most important results found.es
dc.formatapplication/vnd.ms-exceles
dc.language.isoenges
dc.relation.isreferencedbyTejero González, A. y Franco Salas, A. (2021). Optimal operation of evaporative cooling pads: A review. Renewable and Sustainable Energy Reviews, 2021 (151), 1 p.-14 p. https://doi.org/10.1016/j.rser.2021.111632es
dc.relation.isreferencedbyhttps://idus.us.es/handle/11441/135824
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectEnfriamiento evaporativo directoes
dc.subjectPanel de enfriamiento evaporativoes
dc.subjectAire acondicionadoes
dc.subjectEficiencia de enfriamientoes
dc.subjectEficacia de saturaciónes
dc.subjectPérdida de cargaes
dc.subjectDirect evaporative coolinges
dc.subjectEvaporative cooling pades
dc.subjectAir conditioninges
dc.subjectCooling efficiencyes
dc.subjectSaturation effectivenesses
dc.subjectPressure dropes
dc.titleOptimal_operation_evaporative_cooling_pads_review_[dataset]es
dc.title.alternativeOptimal operation of evaporative cooling pads: A review [Dataset]es
dc.typeinfo:eu-repo/semantics/datasetes
dc.description.versionv.1es
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Aeroespacial y Mecánica de Fluidoses
dc.relation.projectIDVA272P18es
dc.identifier.doi10.12795/11441/153904
dc.contributor.groupUniversidad de Sevilla. AGR 268: Naturación Urbana e Ingeniería de Biosistemases
dc.contributor.funderJunta de Castilla y León. Consejería de Educaciónes
dc.contributor.funderEuropean Regional Development Fund (ERDF)es
dc.contributor.datacuratorFranco Salas, Antonioes
dc.type.resourcetypeDatos numéricoses
dc.type.resourcetypeTablases
dc.type.resourcetypeBibliografíases

FicherosTamañoFormatoVerDescripción
Optimal_operation_evaporative_ ...208.9KbIcon   [Microsoft Excel 2007] Ver/Abrir
Readme para datos opensource_O ...2.734KbIcon   [Fichero de texto] Ver/Abrir

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución-NoComercial-CompartirIgual 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución-NoComercial-CompartirIgual 4.0 Internacional