Mostrar el registro sencillo del ítem

Artículo

dc.creatorAzcarate-Velázquez, Franciscoes
dc.creatorCastillo-Oyagüe, Raqueles
dc.creatorOliveros-López, Luis Guillermoes
dc.creatorTorres-Lagares, Danieles
dc.creatorMartínez-González, Álvaro Josées
dc.creatorPérez-Velasco, Andreaes
dc.creatorLynch, Christopher D.es
dc.creatorGutiérrez Pérez, José Luises
dc.creatorSerrera Figallo, María de los Ángeleses
dc.date.accessioned2023-12-29T11:57:50Z
dc.date.available2023-12-29T11:57:50Z
dc.date.issued2019
dc.identifier.citationAzcarate-Velázquez, F., Castillo-Oyagüe, R., Oliveros-López, L.G., Torres-Lagares, D., Martínez-González, Á.J., Pérez-Velasco, A.,...,Serrera Figallo, M.d.l.Á. (2019). Influence of bone quality on the mechanical interaction between implant and bone: A finite element analysis. Journal of Dentistry, 88, UNSP 103161. https://doi.org/10.1016/j.jdent.2019.06.008.
dc.identifier.issn0300-5712es
dc.identifier.urihttps://hdl.handle.net/11441/152867
dc.description.abstractObjectives: To evaluate the influence of bone type in terms of bone density and cortical bone thickness, on the stresses induced by two implants under compressive and oblique loads. Methods: A numerical simulation technique based on the finite element method was applied. Two implant types (M-12 and Astra Tech) were introduced in a model matrix whose geometry was extracted from a real CBCT radiograph of the posterior mandibular region. The Young’s module and Poisson’s coefficient of the bone qualities described by Misch were calculated. Loads with amplitude of 400 N were exerted in two directions: compressive and 15° oblique to 5 mm above the uppermost part of the implant. Results: The von Misses variant was analysed. Both implant types presented greater tension in the cortical bone area than in the trabecular bone region under compressive loading. For the oblique load condition, the stresses obtained in the cortical zone were significantly higher than those registered as a consequence of compressive loads in both implant types. Conclusions: Regardless of bone type, the M-12 implants presented lower tensions in the cortical bone than did the Astra implants. The tensions recorded for D3 and D4 bone types in the trabecular zone surrounding the M-12 implants were greater than those recorded for the Astra implants. Clinical significance: For both compressive and oblique loads, good mechanical behaviour was observed. The decrease in bone quality determines a worse stress distribution, and the cortical bone is overloaded. An efficient distribution of the forces may increase the implants’ longevity.es
dc.formatapplication/pdfes
dc.format.extent16 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofJournal of Dentistry, 88, UNSP 103161.
dc.subjectDental implantses
dc.subjectBone qualityes
dc.subjectFinite element analysises
dc.titleInfluence of bone quality on the mechanical interaction between implant and bone: A finite element analysises
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/submittedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0300571219301320?via%3Dihubes
dc.identifier.doi10.1016/j.jdent.2019.06.008es
dc.journaltitleJournal of Dentistryes
dc.publication.volumen88es
dc.publication.initialPageUNSP 103161es

FicherosTamañoFormatoVerDescripción
Influence of...pdf1.231MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.