Mostrar el registro sencillo del ítem

Artículo

dc.creatorSánchez González, José Maríaes
dc.creatorAlonso Aliste, Federicoes
dc.creatorPerea Peña, Graciaes
dc.creatorRachwani-Anil, Rahules
dc.creatorMárquez de Aracena del Cid, Rafaeles
dc.creatorRocha de Lossada, Carloses
dc.date.accessioned2023-12-13T16:10:44Z
dc.date.available2023-12-13T16:10:44Z
dc.date.issued2020-08
dc.identifier.citationSánchez González, J.M., Alonso Aliste, F., Perea Peña, G., Rachwani-Anil, R., Márquez de Aracena del Cid, R. y Rocha de Lossada, C. (2020). Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation. International Ophthalmology, 40 (8), 2047-2053. https://doi.org/10.1007/s10792-020-01381-w.
dc.identifier.issn0165-5701es
dc.identifier.issn1573-2630es
dc.identifier.urihttps://hdl.handle.net/11441/152451
dc.description.abstractPurpose: To evaluate 1-year changes of vault, anterior chamber angle width (ACAW) and intraocular pressure (IOP) after the implantation of implantable collamer lens (ICL) V4c in high myopic patients. Methods: Sixty ICL V4c implantation surgeries were included. Patients underwent surgery between January 2014 and June 2017 at Ophthalmology Center Tecnolaser Clinic Vision®, Seville, Spain. All patients had a 12-month follow-up. A preoperative spherical equivalent between − 4.00 and − 15.00 D was established as inclusion criterion. ACAW and vault were measured with Pentacam single rotation Scheimpflug camera (Oculus Optikgeräte GmbH, Wetzlar, Germany). IOP was measured with CORVIS ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). Results: One-day vault was 553.17 ± 169.80 [268–975] µm; 12-month vault was 515.67 ± 176.46 [169–950] µm (p < 0.01). Preoperative ACAW was 36.85° ± 4.60° [26.7°–46.8°]; postoperative ACAW was 25.98° ± 3.85° [16.4°–32.6°] (p < 0.01). Preoperative IOP was 15.37 ± 1.58 [12.0–18.3] mmHg, postoperative IOP was 15.61 ± 1.60 [12.0–19.0] mm Hg (p = 0.35). Conclusions: ICL V4c lens experienced a progressive reduction of vault after 12-month follow-up. ACAW decrease was significant between preoperative and postoperative values. We propose to include a minimum preoperative ACAW and an IOP correction factor for lens size.es
dc.formatapplication/pdfes
dc.format.extent17 p.es
dc.language.isoenges
dc.publisherSpringer Naturees
dc.relation.ispartofInternational Ophthalmology, 40 (8), 2047-2053.
dc.subjectAnterior chamber angle widthes
dc.subjectCentral vaultes
dc.subjectImplantable collamer lenses
dc.subjectIntraocular phakic lenses
dc.subjectIntraocular pressurees
dc.subjectPosterior chamber phakic lenses
dc.titleAnterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantationes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Cirugíaes
dc.relation.publisherversionhttps://doi.org/10.1007/s10792-020-01381-wes
dc.identifier.doi10.1007/s10792-020-01381-wes
dc.journaltitleInternational Ophthalmologyes
dc.publication.volumen40es
dc.publication.issue8es
dc.publication.initialPage2047es
dc.publication.endPage2053es

FicherosTamañoFormatoVerDescripción
Anterior Chamber Angle.pdf847.6KbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.