Mostrar el registro sencillo del ítem

Capítulo de Libro

dc.contributor.editorGómez Villa, José Luises
dc.creatorSendra, Juan J.es
dc.creatorSuárez, Rafaeles
dc.creatorLeón-Rodríguez, Ángel Luises
dc.creatorMartínez Hervás, Mónicaes
dc.date.accessioned2023-11-29T09:20:18Z
dc.date.available2023-11-29T09:20:18Z
dc.date.issued2019
dc.identifier.citationSendra, J.J., Suárez, R.,...,Martínez Hervás, M. (2019). Investigación teórica y constructiva: comportamiento ambiental y energético. En J.L. Gómez Villa (Ed.), re-HABITAR el Carmen: Un proyecto sobre patrimonio contemporáneo (pp. 216-227). Sevilla: Junta de Andalucía, Consejería de Cultura y Patrimonio Histórico.
dc.identifier.isbn9788499593449es
dc.identifier.urihttps://hdl.handle.net/11441/151816
dc.description.abstractEl importante parque residencial de las décadas de los 50 a los 70 fue construido sin ningún tipo de regulación normativa referente a criterios ambientales y energéticos, por lo que en la actualidad adolece de diferentes grados de obsolescencia, no respondiendo a las actuales exigencias en materia energética. Esta investigación sobre el comportamiento ambiental y energético de la barriada de El Carmen pretende responder a estas dos etapas temporales, conociendo su comportamiento en su estado actual y valorando su capacidad de mejora mediante diferentes propuestas de rehabilitación energética compatibles con su carácter patrimonial. Para caracterizar energéticamente tanto los bloques en torre como los lineales, se ha realizado un trabajo de campo que ha permitido conocer el grado de permeabilidad al aire, caracterizar su envolvente térmica, así como conocer los sistemas de acondicionamiento e instalaciones para la habitabilidad y el confort. En este sentido, los sistemas de producción de agua caliente sanitaria (ACS) dominantes actualmente son los de tipo eléctrico o de gas natural. Los equipos de calefacción utilizados en la mayoría de las viviendas son generadores de calor locales y portátiles de tipo eléctrico, mientras que los de refrigeración son equipos de expansión directa, partidos tipo split. Este trabajo se ha complementado con el análisis energético mediante modelos de simulación. La barriada de El Carmen presenta, en su estado actual, una calificación energética E, considerada aceptable en relación con edificaciones de su época, pero claramente insuficiente para las exigencias actuales, como se desprende de los elevados valores de demanda, especialmente en régimen de invierno. Así, existe un gran distanciamiento de los valores de la demanda energética de calefacción con los valores normativos. En ambos tipos de bloques hay un claro exceso de demanda de calefacción sobre este valor límite: alrededor de cuatro veces superior. Sin embargo, en cuanto a la demanda energética de refrigeración este distanciamiento es mucho menor: un 64 % en la torre en altura y un 74 % en el bloque lineal, aproximadamente. No obstante, existe un importante margen de mejora: mediante adecuadas estrategias de rehabilitación, se podrían reducir las emisiones de CO2 en el orden de un 20 %, y la demanda energética global en un 30 %. En concreto, todas las propuestas de rehabilitación analizadas de los bloques lineales y en torre ofrecen resultados muy similares, consiguiendo una reducción de las emisiones de CO2 del 17 y 21 % anuales, y de la demanda energética global del 26 y 27 % anuales, respectivamente.es
dc.description.abstractThe substantial number of residential buildings constructed between the 1950s and 1970s had no regulatory framework governing environmental and energy criteria; as a result, today they are more or less obsolete and do not meet current standards of energy efficiency. This study of the environmental and energy performance of the neighbourhood of El Carmen aimed to analyse both time periods, determining how they perform today and assessing their potential for improvement with different energyefficient renovation proposals compatible with their heritage value. In order to characterise the energy efficiency of both the tower and terraced blocks, fieldwork was carried out to determine air tightness, characterise the thermal envelope, and understand the conditioning systems and utilities for habitability and comfort. In this respect, the predominant hot water supply systems are those fuelled by electricity or natural gas. The majority of homes are heated by local and portable electric heat generators, while cooling is generally provided by split-type direct expansion systems. This fieldwork was complemented by an energy analysis with simulation models. In its current condition, the neighbourhood of El Carmen has an energy rating of E, which is considered acceptable in comparison with other buildings of the same age but clearly insufficient by modern standards, as illustrated by the high levels of demand, especially in the winter months. Consequently, there is a wide gap between levels of heating energy demand and standard levels. Heating demand in both types of buildings is roughly four times higher than this benchmark level. However, the distance is much narrower with regard to cooling demand: 64% in tower blocks and 74% in terraced blocks, approximately. Even so, there is significant room for improvement: appropriate renovation strategies could reduce CO2 emissions by around 20% and overall energy demand by 30%. Specifically, all renovation proposals considered for the terraced and tower blocks offer very similar results, reducing annual CO2 emissions by 17% and 21% and overall annual energy demand by 26% and 27%, respectively.es
dc.formatapplication/pdfes
dc.format.extent6 p.es
dc.language.isospaes
dc.publisherJunta de Andalucía, Consejería de Cultura y Patrimonio Históricoes
dc.relation.ispartofre-HABITAR el Carmen: Un proyecto sobre patrimonio contemporáneoes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectArquitecturaes
dc.subjectMovimiento modernoes
dc.subjectComportamiento ambiental y energéticoes
dc.subjectEmisiones de CO2es
dc.titleInvestigación teórica y constructiva: comportamiento ambiental y energéticoes
dc.title.alternativeTheoretical and constructive research: Environmental and energy performancees
dc.typeinfo:eu-repo/semantics/bookPartes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas I (ETSA)es
dc.contributor.groupUniversidad de Sevilla. TEP130: Arquitectura, Patrimonio y Sostenibilidad: Acústica, Iluminación, Óptica y Energíaes
dc.publication.initialPage216es
dc.publication.endPage227es
dc.relation.publicationplaceSevillaes

FicherosTamañoFormatoVerDescripción
Investigación teórica y constr ...504.7KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional