Mostrar el registro sencillo del ítem

Artículo

dc.creatorEndrino, José Luises
dc.creatorAllen, Matthewes
dc.creatorEscobar-Galindo, Ramónes
dc.creatorZhang, Hanshenes
dc.creatorAnders, Andrées
dc.creatorAlbella Martín, José Maríaes
dc.date.accessioned2023-06-30T10:20:05Z
dc.date.available2023-06-30T10:20:05Z
dc.date.issued2007-04-18
dc.identifier.citationEndrino, J.L., Allen, M., Escobar-Galindo, R., Zhang, H., Anders, A. y Albella Martín, J.M. (2007). Biocompatible Silver-containing a-C:H and a-C coatings: A Comparative Study. MRS Online Proceedings Library, 950. https://doi.org/10.1557/PROC-0950-D08-02.
dc.identifier.issn1946-4274 (online)es
dc.identifier.urihttps://hdl.handle.net/11441/147590
dc.description.abstractHydrogenated diamond-like-carbon (a-C:H) and hydrogen-free amorphous carbon (a-C) coatings are known to be biocompatible and have good chemical inertness. For this reason, both of these materials are strong candidates to be used as a matrix that embeds metallic elements with antimicrobial effect. In this comparative study, we have incorporated silver into standard diamond-like carbon (DLC) coatings by plasma ion implantation and deposition (PIII&D) using methane (CH4) plasma and simultaneously depositing Ag from a pulsed cathodic arc source. In addition, we have grown amorphous carbon – silver composite coatings using a dual-cathode pulsed filtered cathodic-arc (FCA) source. The silver atomic content of the deposited samples was analyzed using glow discharge optical spectroscopy (GDOES). In both cases, the arc pulse frequency of the silver cathode was adjusted in order to obtain samples with approximately 5 at.% of Ag. Surface hardness of the deposited films was analyzed using the nanoindentation technique. Cell viability for both a-C:H/Ag and a-C:/Ag samples deposited on 24-well tissue culture plates has been evaluated.es
dc.formatapplication/pdfes
dc.format.extent7es
dc.language.isoenges
dc.publisherSpirngerLinkes
dc.relation.ispartofMRS Online Proceedings Library, 950.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleBiocompatible Silver-containing a-C:H and a-C coatings: A Comparative Studyes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Aplicada Ies
dc.relation.publisherversionhttps://link.springer.com/article/10.1557/PROC-0950-D08-02es
dc.identifier.doi10.1557/PROC-0950-D08-02es
dc.journaltitleMRS Online Proceedings Libraryes
dc.publication.issue950es

FicherosTamañoFormatoVerDescripción
qt8hj196zs_noSplash_5fee3b8336 ...674.2KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional