dc.creator | Gutiérrez de San Miguel Herrera, Enrique | es |
dc.creator | Pérez Moreno, J. P. | es |
dc.creator | Bolívar, Juan Pedro | es |
dc.creator | García-Tenorio García-Balmaseda, Rafael | es |
dc.date.accessioned | 2023-05-19T18:04:47Z | |
dc.date.available | 2023-05-19T18:04:47Z | |
dc.date.issued | 2004 | |
dc.identifier.citation | Gutiérrez de San Miguel Herrera, E., Pérez Moreno, J.P., Bolívar, J.P. y García-Tenorio García-Balmaseda, R. (2004). A semi-empirical approach for determination of low-energy gamma-emmiters in sediment samples with coaxial Ge-detectors. Applied Radiation and Isotopes, 61 (2-3), 361-366. https://doi.org/10.1016/j.apradiso.2004.03.009. | |
dc.identifier.issn | 1872-9800 | es |
dc.identifier.issn | 0969-8043 | es |
dc.identifier.uri | https://hdl.handle.net/11441/146473 | |
dc.description.abstract | A simple method for the determination in sediment samples of low-energy gamma-emitters with coaxial Ge detectors
and using a cylindrical sample geometry is outlined. This method allows an easy estimation of self-absorption effects by
knowing the apparent densities and the composition of the investigated samples. As calibration matrixes solid samples
enriched in known amounts of natural radionuclides emitting low-energy gamma rays were used. In this way, the
difficult homogenisation steps needed when liquid spikes are added to a solid blank for manufacturing the calibration
sample are avoided.
The method has been carefully checked and validated by applying it to sediment samples with known activities of
some low-energy gamma-ray emitters. Additionally, these sediment measurements have allowed to evaluate the
magnitude and importance of the self-absorption corrections. | es |
dc.format | application/pdf | es |
dc.format.extent | 7 p. | es |
dc.language.iso | eng | es |
dc.publisher | Elsevier | es |
dc.relation.ispartof | Applied Radiation and Isotopes, 61 (2-3), 361-366. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | A semi-empirical approach for determination of low-energy gamma-emmiters in sediment samples with coaxial Ge-detectors | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Aplicada II | es |
dc.relation.publisherversion | https://doi.org/10.1016/j.apradiso.2004.03.009 | es |
dc.identifier.doi | 10.1016/j.apradiso.2004.03.009 | es |
dc.journaltitle | Applied Radiation and Isotopes | es |
dc.publication.volumen | 61 | es |
dc.publication.issue | 2-3 | es |
dc.publication.initialPage | 361 | es |
dc.publication.endPage | 366 | es |