Mostrar el registro sencillo del ítem

Artículo

dc.creatorGarcía Jiménez, Rocíoes
dc.creatorGarcía Mejido, José Antonioes
dc.creatorValero, Irenees
dc.creatorFernández Palacín, Anaes
dc.creatorBorrero González, Carlotaes
dc.creatorSáinz Bueno, José Antonioes
dc.date.accessioned2023-05-16T12:55:44Z
dc.date.available2023-05-16T12:55:44Z
dc.date.issued2022
dc.identifier.citationGarcía Jiménez, R., García Mejido, J.A., Valero, I., Fernández Palacín, A., Borrero González, C. y Sáinz Bueno, J.A. (2022). Intra- and Interobserver Reliability of Superb Microvascular Imaging (SMI) Doppler for Assessing Placental Microvasculature. CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 49 (8), 177. https://doi.org/doi.org/10.31083/j.ceog4908177.
dc.identifier.issn0390-6663es
dc.identifier.urihttps://hdl.handle.net/11441/146131
dc.description.abstractObjective: Superb Microvascular Imaging (SMI) Doppler is a novel technique. We aim to evaluate intra- and interobserver reliability of SMI Doppler for the assessment of normal placental microvasculature. Materials and Methods: A prospective observational study was conducted including 11 pregnant patients. Ultrasonography placental assessment was performed on 28-weeks pregnant patients, by two expert examiners using SMI Doppler in one single visit. To evaluate interobserver reliability, the first examiner took measurements using SMI Doppler, followed then by the second examiner. Afterwards, the first examiner performed a second evaluation, in order to assess intraobserver reliability. Intraclass correlation coefficients (ICC) and Cohen’s Kappa coefficient, and their 95% confidence intervals, were estimated for quantitative and qualitative parameters, respectively. Results: Intraobserver reliability was found to be excellent for all quantitative parameters, with all ICC values above 0.97. For qualitative variables, excellent reliability was obtained for the number of secondary villi, while the number of tertiary villi had an adequate reliability with a Cohen’s Kappa coefficient of 0.792 (95% CI 0.38–1.17; p = 0.007). Interobserver ICCs ranged from 0.92 to 1.00 for all quantitative parameters, thus finding excellent interobserver reliability for all of them. An excellent reliability was also obtained for the number of secondary villi, while the reliability for the number of tertiary villi was found to be adequate. Conclusions: Our findings show that placental microvasculature measurements obtained by a single or two different examiners are reliable and reproducible. The good intra- and interobserver reliability results of SMI Doppler showed in our study stress the value of this technique in the evaluation of placental microvasculature, and thus research in this field is the step forward for the assessment of placental insufficiency.es
dc.formatapplication/pdfes
dc.format.extent6 p.es
dc.language.isoenges
dc.publisherI R O G CANADA, INCes
dc.relation.ispartofCLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 49 (8), 177.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectSuperb microvascular imaginges
dc.subjectSMI Doppleres
dc.subjectPlacental microvasculaturees
dc.subjectReproducibilityes
dc.subjectReliabilityes
dc.titleIntra- and Interobserver Reliability of Superb Microvascular Imaging (SMI) Doppler for Assessing Placental Microvasculaturees
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Cirugíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Medicina Preventiva y Salud Públicaes
dc.relation.publisherversionhttps://www.imrpress.com/journal/CEOG/49/8/10.31083/j.ceog4908177es
dc.identifier.doidoi.org/10.31083/j.ceog4908177es
dc.journaltitleCLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGYes
dc.publication.volumen49es
dc.publication.issue8es
dc.publication.initialPage177es

FicherosTamañoFormatoVerDescripción
Intra and Interobserver.pdf4.004MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional