Mostrar el registro sencillo del ítem

Artículo

dc.creatorHerrero-Climent, Marianoes
dc.creatorFalcao, Artures
dc.creatorTondela, Joaoes
dc.creatorBrizuela, Aritzaes
dc.creatorRíos Carrasco, Blancaes
dc.creatorGil, Javieres
dc.date.accessioned2023-04-21T13:23:30Z
dc.date.available2023-04-21T13:23:30Z
dc.date.issued2023
dc.identifier.citationHerrero-Climent, M., Falcao, A., Tondela, J., Brizuela, A., Ríos Carrasco, B. y Gil, J. (2023). Relevant aspects of the dental implant design on the insertion torque, resonance frequency analysis (RFA) and micromobility: an in vitro study. JOURNAL OF CLINICAL MEDICINE, 12 (3), 855. https://doi.org/10.3390/jcm12030855.
dc.identifier.issn2077-0383es
dc.identifier.urihttps://hdl.handle.net/11441/144749
dc.description.abstractThe major problems for the osseointegration of dental implants are the loosening of the screw that fixes the dental implant to the abutment and the micromovements that are generated when mechanical loads are applied. In this work, torque differences in the tightening and loosening of the connection screws after 1 cycle, 10 cycles and 1000 cycles for 4 dental implants with 2 external and 2 internal connections were analyzed. The loosening of 240 implants (60 for each system) was determined using high-precision torsimeters and an electromechanical testing machine. A total of 60 dental implants for each of the 4 systems were inserted into fresh bovine bone to determine the micromovements. The implant stability values (ISQ) were determined by RFA. The mechanical loads were performed at 30 from 20 N to 200 N. By means of the Q-star technique, the micromovements were determined. It was observed that, for a few cycles, the loosening of the screw did not exceed a loss of tightening of 10% for both connections. However, for 1000 cycles, the loss for the external connection was around 20% and for the internal connection it was 13%. The micromovements showed a lineal increase with the applied load for the implant systems studied. An external connection presented greater micromotions for each level of applied load and lower ISQ values than internal ones. An excellent lineal correlation between the ISQ and micromobility was observed. These results may be very useful for clinicians in the selection of the type of dental implant, depending on the masticatory load of the patient as well as the consequences of the insertion torque of the dental implant and its revisions.es
dc.description.sponsorshipMinisterio de Ciencia e Innovación, Españaes
dc.formatapplication/pdfes
dc.format.extent13 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofJOURNAL OF CLINICAL MEDICINE, 12 (3), 855.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectDental implantes
dc.subjectTorque insertiones
dc.subjectExternal connectiones
dc.subjectInternal connectiones
dc.subjectMicromobilityes
dc.subjectResonance frequency analysises
dc.titleRelevant aspects of the dental implant design on the insertion torque, resonance frequency analysis (RFA) and micromobility: an in vitro studyes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.projectIDPDC2022-133628-C22es
dc.relation.publisherversionhttps://www.mdpi.com/2077-0383/12/3/855es
dc.identifier.doi10.3390/jcm12030855es
dc.journaltitleJOURNAL OF CLINICAL MEDICINEes
dc.publication.volumen12es
dc.publication.issue3es
dc.publication.initialPage855es

FicherosTamañoFormatoVerDescripción
Relevant Aspects...pdf2.563MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional