Mostrar el registro sencillo del ítem

Trabajo Fin de Grado

dc.contributor.advisorLópez Muñoz, Alfredoes
dc.contributor.advisorGarcía Romera, Marta de la Concepciónes
dc.creatorLópez Castaño, Isabeles
dc.date.accessioned2023-03-20T14:25:40Z
dc.date.available2023-03-20T14:25:40Z
dc.date.issued2022
dc.identifier.citationLópez Castaño, I. (2022). Estudio biomecánico corneal medido con un analizador dinámico Scheimpflug en usuarios de lentes de contacto blandas. (Trabajo Fin de Grado Inédito). Universidad de Sevilla, Sevilla.
dc.identifier.urihttps://hdl.handle.net/11441/143479
dc.description.abstractLa biomecánica corneal es una ciencia que trata el equilibrio y la deformación del tejido sometido a cualquier fuerza, tomando como referencia la unión de conocimientos físico – matemáticos, arquitectónicos, mecánicos y biológicos. Estudia la función y estructura de la córnea y establece bases para predecir su respuesta dinámica ante situaciones fisiológicas y patológicas. Predecir el comportamiento biomecánico de la córnea es esencial para comprender las consecuencias derivadas de la geometría de la primera superficie corneal y es por lo que hay constante incremento en su estudio y medición. Y es que, aunque las técnicas para su medición in vivo son limitadas, se llegó a la conclusión de que un método rentable para ello es el analizador dinámico Scheimpflug Corvis ST. El objetivo principal de este proyecto es caracterizar el impacto de las lentes de contacto blandas sobre la biomecánica corneal de sus usuarios, medida con tecnología Scheimpflug a través del analizador Corvis ST. Para llevarlo a cabo, se escogió una muestra de 23 sujetos portadores de lentes de contacto con miopía simple o compuesta. A estos, se les realizaron dos medidas con Corvis ST, una previa y otra tras portar un par de lentes de contacto mensuales. Tras analizar los resultados obtenidos se llega a la conclusión de que los índices biomecánicos aportados por el Corvis demuestran seguridad en cuanto a la adaptación de lentes de contacto en pacientes miopes sanos.es
dc.description.abstractCorneal biomechanics is a science that deals with the equilibrium and deformation of tissue subjected to any force, taking as a reference the union of physical-mathematical, architectural, mechanical, and biological knowledge. It studies the function and structure of the cornea and establishes the basis for predicting its dynamic response to physiological and pathological situations. Predicting the biomechanical behavior of the cornea is essential to understand the consequences derived from the geometry of the first corneal surface and that is why there is a constant increase in its study and measurement. Although the techniques for its measurement in vivo are limited, it was concluded that a cost-effective method for this purpose is the Scheimpflug Corvis ST dynamic analyzer. The main objective of this project is to characterize the impact of soft contact lenses on the corneal biomechanics of their users, measured with Scheimpflug technology through the Corvis ST analyzer. To carry it out, a sample of 23 subjects wearing contact lenses with simple or compound myopia was chosen. These subjects underwent two measurements with Corvis ST, one before and one after wearing a pair of monthly contact lenses. After analyzing the results obtained, it was concluded that the biomechanical indexes provided by Corvis demonstrate safety in the fitting of contact lenses in healthy myopic patients.es
dc.formatapplication/pdfes
dc.format.extent41 p.es
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectBiomechanicses
dc.subjectCorneaes
dc.subjectContact lenseses
dc.titleEstudio biomecánico corneal medido con un analizador dinámico Scheimpflug en usuarios de lentes de contacto blandases
dc.title.alternativeCorneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyzer in Soft Contact Lens Wearerses
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.description.degreeUniversidad de Sevilla. Grado en Óptica y Optometríaes

FicherosTamañoFormatoVerDescripción
LOPEZ CASTAÑO ISABEL.pdf956.3KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional