Mostrar el registro sencillo del ítem

Artículo

dc.creatorLópez Muñoz, Alfredoes
dc.creatorGargallo Martínez, Beatrizes
dc.creatorSánchez González, María del Carmenes
dc.creatorCapote Puente, Raúles
dc.creatorHita Cantalejo, María Concepción dees
dc.creatorRomero Luna, Martaes
dc.creatorConejero Domínguez, Juan Josées
dc.creatorSánchez González, José Maríaes
dc.date.accessioned2023-03-17T16:28:52Z
dc.date.available2023-03-17T16:28:52Z
dc.date.issued2023
dc.identifier.citationLópez Muñoz, A., Gargallo Martínez, B., Sánchez González, M.d.C., Capote Puente, R., Hita Cantalejo, M.C.d., Romero Luna, M.,...,Sánchez González, J.M. (2023). Key Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology. Key Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology, 13 (2), 447. https://doi.org/10.3390/life13020447.
dc.identifier.issn2075-1729es
dc.identifier.urihttps://hdl.handle.net/11441/143454
dc.description.abstractThe aim of this study was to evaluate the relationship between myopia and ocular biometric variables using the Pentacam AXL® single rotation Scheimpflug camera. This prospective, cross-sectional, single-center study was performed in fifty Caucasian patients aged between 18 and 30 years (24.84 ± 3.04 years). The measured variables included maximum and minimum keratometry (K1 and K2, respectively), anterior chamber depth (ACD), corneal horizontal diameter or white to white (WTW), central corneal thickness (CCT), corneal asphericity (Q), and axial length (AXL). The tomographic and biometric measurements were considered optimal when the quality factor was greater than 95% according to the manufacturer’s software instructions. The AXL presented a significant correlation with the spherical equivalent without cycloplegia (SE without CP), age at onset of myopia (r = −0.365, p = 0.012), mean keratometry (Km) (r = −0.339, p = 0.016), ACD (r = 0.304, p = 0.032), and WTW (r = 0.406, p = 0.005). The eyes with AXL higher than 25 mm had earlier onset; higher SE without CP, AXL, and Q; and a flatter Km. AXL is the biometric variable with the greatest influence on the final refractive state in the adult myopic eye. Ophthalmologists and optometric management must consider these biometric differences in order to identify the most appropriate correction techniques in each case. The use of the Pentacam AXL in ocular biometric measurement is effective, reproducible, and non-invasive.es
dc.formatapplication/pdfes
dc.format.extent12 p.es
dc.language.isoenges
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)es
dc.relation.ispartofKey Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology, 13 (2), 447.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectAxial lengthes
dc.subjectEarly diagnosises
dc.subjectMyopia progressiones
dc.subjectOcular biometryes
dc.subjectScheimpflug technologyes
dc.titleKey Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technologyes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.relation.publisherversionhttps://doi.org/10.3390/life13020447es
dc.identifier.doi10.3390/life13020447es
dc.journaltitleKey Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technologyes
dc.publication.volumen13es
dc.publication.issue2es
dc.publication.initialPage447es

FicherosTamañoFormatoVerDescripción
Key Factors in Early Diagnosis.pdf1.465MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional