dc.contributor.advisorGuerrero Delgado, María del Carmenes
dc.contributor.advisorPalomo Amores, Teresa Rocíoes
dc.creatorGalindo Fernández, Francisco Javieres
dc.date.accessioned2022-12-21T14:56:02Z
dc.date.available2022-12-21T14:56:02Z
dc.date.issued2022
dc.identifier.citationGalindo Fernández, F.J. (2022). Estudio y optimización de la red de climatización y ventilación asociada al edificio de hora del Real Instituto y Observatorio de la Armada en San Fernando. (Trabajo Fin de Grado Inédito). Universidad de Sevilla, Sevilla.
dc.identifier.urihttps://hdl.handle.net/11441/140736
dc.description.abstractEl Real Instituto y Observatorio de la Armada es un Centro de la Armada, ubicado en la ciudad de San Fernando (Cádiz), con casi 270 años de existencia y una amplia tradición en Ciencias de la Tierra y del Espacio. Sus comienzos estuvieron ligados a la determinación de la longitud terrestre en alta mar a partir de medios astronómicos, de donde surge la necesidad de conocer y profundizar en la medida del tiempo. El grado de especialización en esta disciplina llegó a tal punto en los años 70 del siglo pasado, que a principios de esa década se crea la Sección de Hora, escindiéndose de la Sección de Astronomía del Observatorio, a la que pertenecía como un Servicio. Desde el año 1976, el Laboratorio de la Sección de Hora mantiene el patrón de la unidad básica de tiempo y la hora oficial española. Como consecuencia de las exigencias, cada vez mayores, existentes en el ámbito de la metrología del tiempo y la frecuencia, ante el compromiso de desarrollar nuevos relojes atómicos de tipo óptico, que representan el estado de la técnica en la actualidad, de prestar apoyo como Proveedor de Servicios de Tiempo al Sistema Global de Navegación por Satélites Galileo, y de atender las necesidades de tiempo y frecuencia precisos de la sociedad actual, se proyectó un nuevo edificio técnico que fue inaugurado en el 2017. El edificio cuenta, entre otras peculiaridades, con un sistema de climatización todo-aire con baterías de agua, con una etapa de producción frío/calor y dos unidades climatizadoras, que dan servicio a través de los conductos de impulsión a todos los laboratorios y salas con requisitos restrictivos de condiciones ambientales. Desde su puesta en funcionamiento, la planta climatizadora ha mostrado muchas dificultades para mantener las condiciones de los locales conforme a especificaciones. Particularmente la humedad relativa suele estar al límite, o fuera de los rangos de tolerancia establecidos. Además, se observa mucha inercia en la respuesta a los cambios de temperatura en algunos locales, sin que se logre alcanzar la temperatura de consigna en alguno de ellos. Ante todas estas dificultades, se presenta el problema de que el Observatorio no ha contado hasta la fecha con personal dedicado expresamente al manejo y mantenimiento de esta instalación. Por otra parte, el personal científico y técnico de la Sección de Hora ha recibido una formación muy elemental en relación con la comprensión y manejo de la planta climatizadora, y la documentación técnica disponible relativa a la instalación es escasa. Con este trabajo se ha pretendido efectuar el análisis pormenorizado de la planta climatizadora, con objeto de entender con el mayor detalle posible su funcionamiento, y permitir efectuar la mejor elección de los parámetros de consigna que lleven a un funcionamiento eficiente. Estos parámetros de consigna han sido asimismo estimados como parte del trabajo.es
dc.description.abstractThe Real Instituto y Observatorio de la Armada is a Center of the Spanish Navy, located in the city of San Fernando (Cádiz), with almost 270 years of existence and a long tradition in Earth and Space Sciences. Its beginnings were linked to the determination of the terrestrial longitude in the sea from astronomical means, from which the need to know and deepen the measurement of time arises. The degree of specialization in this discipline reached such a point in the 70s of the last century that at the beginning of that decade the Time Section was created, splitting off from the Observatory's Astronomy Section, to which it belonged as a Service. Since 1976, the Time Section Laboratory has maintained the standard of the basic unit of time, and the Spanish official time. As a consequence of the growing demands in the field of time and frequency metrology, given the commitment to develop new optical-type atomic clocks, which represent nowadays the state of the art, to support the Galileo GNSS as a Time Service Provider, and to meet the needs of precise time and frequency of today's society, a new technical building was designed and inaugurated in 2017. The building has, among other features, an integral air conditioning system with water batteries, with a cold/heat production stage and two air conditioning units, which provide service through the supply ducts to all the laboratories and rooms with restrictive requirements of environmental conditions. Since its commissioning, the air conditioning plant has shown many difficulties in maintaining the conditions of the premises according to the specifications. In particular, the relative humidity is often at the limit, or outside the established tolerance ranges. In addition, a lot of inertia is observed in the response to temperature changes in some rooms, without some of them reaching the setpoint temperature. Given all these difficulties, the problem arises that the Observatory has not had personnel specifically dedicated to the management and maintenance of this facility to date. On the other hand, the scientific and technical personnel of the Time Section have received very elementary training in relation to knowledge and management of the air conditioning plant, and the technical documentation available on the installation is scarce. With this work it has been tried to carry out a detailed analysis of the air conditioning plant, in order to understand its operation with the greatest possible detail, and allow the best choice of setpoint parameters that lead to efficient operation. These setpoint parameters have also been estimated as part of the work.es
dc.formatapplication/pdfes
dc.format.extent91 p.es
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEstudio y optimización de la red de climatización y ventilación asociada al edificio de hora del Real Instituto y Observatorio de la Armada en San Fernandoes
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Energéticaes
dc.description.degreeUniversidad de Sevilla. Grado en Ingeniería de Tecnologías Industriales.es