Mostrar el registro sencillo del ítem

Artículo

dc.creatorAlmeida, Ritaes
dc.creatorManarte-Monteiro, Patriciaes
dc.creatorDomingues, Joanaes
dc.creatorFalcão, Carloses
dc.creatorHerrero Climent, Marianoes
dc.creatorRíos Carrasco, Blancaes
dc.creatorLemos, Bernardo Ferreiraes
dc.date.accessioned2022-11-23T14:39:14Z
dc.date.available2022-11-23T14:39:14Z
dc.date.issued2021-06-30
dc.identifier.citationAlmeida, R., Manarte-Monteiro, P., Domingues, J., Falcão, C., Herrero-Climent, M., Ríos Carrasco, B. y Lemos, B.F. (2021). High-power LED units currently available for dental resin-based materials—A review. Polymers, 13 (13), 2165. https://doi.org/10.3390/polym13132165.
dc.identifier.issn2073-4360es
dc.identifier.urihttps://hdl.handle.net/11441/139730
dc.description.abstractThe pursuit of less time-consuming procedures led to the development of high-power light-curing-units (LCU) to light-cure dental-resin-based-materials. This review aims to describe high-power light-emitting-diode (LED)-LCUs, by a bibliometric systematization of in vitro and in vivo studies. The research-question, by PICO model, aimed to assess the current knowledge on dentistry-based high-power LED-LCUs by analyzing to what extent their use can promote adverse events on materials and patients’ oral condition when compared to low-power LED-LCUs, on daily dental practice. PubMed and B-on database search focused on high-power (≥2000 mW/cm2 ) LED-LCUs outputs. Studies assessing performance of high-power LED-LCUs for light-curing dental-resin-based-materials were included. From 1822 screened articles, 21 fulfilled the inclusion criteria. Thirty-two marketed units with high levels of radiant emittance (≥2000 mW/cm2 up to 6000 mW/cm2 ) were identified. Most output values vary on 2000–3000 mW/cm2 . The highest output found was 6000 mW/cm2 , in FlashMax™P3. Reports suggest that light-curing protocols with lower emittance irradiance and longer exposure outperforms all other combination, however in some clinical procedures high-power LED-LCUs are advocated when compared to low-power LED-LCUs. Moreover, long time exposures and over-curing can be dangerous to the biological vital pulp, and other oral tissues. Evidence showing that high-power LCUs are the best clinical option is still very scarce.es
dc.formatapplication/pdfes
dc.format.extent30 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofPolymers, 13 (13), 2165.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectDental curing unitses
dc.subjectLED curing-lightses
dc.subjectComposite resinses
dc.subjectAdverse eventses
dc.subjectDental materialSes
dc.titleHigh-power LED units currently available for dental resin-based materials—A reviewes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.publisherversionhttps://www.mdpi.com/2073-4360/13/13/2165es
dc.identifier.doi10.3390/polym13132165es
dc.journaltitlePolymerses
dc.publication.volumen13es
dc.publication.issue13es
dc.publication.initialPage2165es

FicherosTamañoFormatoVerDescripción
High-Power...pdf684.2KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional