dc.creator | Almeida, Rita | es |
dc.creator | Manarte-Monteiro, Patricia | es |
dc.creator | Domingues, Joana | es |
dc.creator | Falcão, Carlos | es |
dc.creator | Herrero Climent, Mariano | es |
dc.creator | Ríos Carrasco, Blanca | es |
dc.creator | Lemos, Bernardo Ferreira | es |
dc.date.accessioned | 2022-11-23T14:39:14Z | |
dc.date.available | 2022-11-23T14:39:14Z | |
dc.date.issued | 2021-06-30 | |
dc.identifier.citation | Almeida, R., Manarte-Monteiro, P., Domingues, J., Falcão, C., Herrero-Climent, M., Ríos Carrasco, B. y Lemos, B.F. (2021). High-power LED units currently available for dental resin-based materials—A review. Polymers, 13 (13), 2165. https://doi.org/10.3390/polym13132165. | |
dc.identifier.issn | 2073-4360 | es |
dc.identifier.uri | https://hdl.handle.net/11441/139730 | |
dc.description.abstract | The pursuit of less time-consuming procedures led to the development of high-power
light-curing-units (LCU) to light-cure dental-resin-based-materials. This review aims to describe
high-power light-emitting-diode (LED)-LCUs, by a bibliometric systematization of in vitro and
in vivo studies. The research-question, by PICO model, aimed to assess the current knowledge on
dentistry-based high-power LED-LCUs by analyzing to what extent their use can promote adverse
events on materials and patients’ oral condition when compared to low-power LED-LCUs, on
daily dental practice. PubMed and B-on database search focused on high-power (≥2000 mW/cm2
)
LED-LCUs outputs. Studies assessing performance of high-power LED-LCUs for light-curing
dental-resin-based-materials were included. From 1822 screened articles, 21 fulfilled the inclusion
criteria. Thirty-two marketed units with high levels of radiant emittance (≥2000 mW/cm2 up to
6000 mW/cm2
) were identified. Most output values vary on 2000–3000 mW/cm2
. The highest
output found was 6000 mW/cm2
, in FlashMax™P3. Reports suggest that light-curing protocols
with lower emittance irradiance and longer exposure outperforms all other combination, however
in some clinical procedures high-power LED-LCUs are advocated when compared to low-power
LED-LCUs. Moreover, long time exposures and over-curing can be dangerous to the biological vital
pulp, and other oral tissues. Evidence showing that high-power LCUs are the best clinical option is
still very scarce. | es |
dc.format | application/pdf | es |
dc.format.extent | 30 p. | es |
dc.language.iso | eng | es |
dc.publisher | MDPI | es |
dc.relation.ispartof | Polymers, 13 (13), 2165. | |
dc.rights | Atribución 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.subject | Dental curing units | es |
dc.subject | LED curing-lights | es |
dc.subject | Composite resins | es |
dc.subject | Adverse events | es |
dc.subject | Dental materialS | es |
dc.title | High-power LED units currently available for dental resin-based materials—A review | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Estomatología | es |
dc.relation.publisherversion | https://www.mdpi.com/2073-4360/13/13/2165 | es |
dc.identifier.doi | 10.3390/polym13132165 | es |
dc.journaltitle | Polymers | es |
dc.publication.volumen | 13 | es |
dc.publication.issue | 13 | es |
dc.publication.initialPage | 2165 | es |