Mostrar el registro sencillo del ítem

Artículo

dc.creatorLeón-López, Maríaes
dc.creatorCabanillas Balsera, Danieles
dc.creatorAreal Quecuty, Victoriaes
dc.creatorMartín González, Jeniferes
dc.creatorJiménez Sánchez, María del Carmenes
dc.creatorSauco Márquez, Juan Josées
dc.creatorSánchez-Domínguez, Benitoes
dc.creatorSegura Egea, Juan Josées
dc.date.accessioned2022-11-17T16:33:37Z
dc.date.available2022-11-17T16:33:37Z
dc.date.issued2021-06-23
dc.identifier.citationLeón-López, M., Cabanillas Balsera, D., Areal Quecuty, V., Martín González, J., Jiménez Sánchez, M.d.C., Sauco Márquez, J.J.,...,Segura Egea, J.J. (2021). Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis. Journal of Clinical Medicine, 10 (3), 2760. https://doi.org/10.3390/jcm10132760.
dc.identifier.issn2077-0383es
dc.identifier.urihttps://hdl.handle.net/11441/139570
dc.description.abstractAim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according to the PRISMA checklist, using the following databases: PubMed, Science Direct, Scopus, and Web of Science. Studies related to WL determination using EAL both in preflared and unflared root canals of extracted human teeth were included. The outcome of interest was the accuracy of the electronic WL determination. A quality assessment of the included studies was performed, determining the risk of bias. The meta-analyses were calculated with the 5.4 RevMan software using the inverse variance method with random effects. PROSPERO registration: CRD42021243412. Results. Ten experimental studies fulfilled the inclusion criteria, and most of them found that preflaring increases the accuracy of the EALs in WL determination. The calculated OR was 1.98 (95% CI = 1.65–2.37; p < 0.00001; I2 = 10%), indicating that the determination of WL by EALs is almost twice as accurate in preflared canals. The accuracy of Root ZX in WL determination increases more than three times (OR = 3.25; p < 0.00001). Preflaring with Protaper files significantly increases the accuracy of EALs (OR = 1.76; p < 0.00001). The total risk of bias of the included studies was low. No obvious publication bias was observed. Conclusions. The results indicate a significant increase in the accuracy of WL determination with EAL after preflaring, doubling the percentage of exact measurements. Preflaring should be recommended as an important step during mechanical enlargement of the root canal, not only because it improves the access of the files to the canal, but also because it allows one to obtain more accurate electronic determinations of WL.es
dc.formatapplication/pdfes
dc.format.extent15 p.es
dc.language.isoenges
dc.publisherhttps://www.mdpi.com/2077-0383/10/13/2760es
dc.relation.ispartofJournal of Clinical Medicine, 10 (3), 2760.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectCervical preflaringes
dc.subjectCoronal preflaringes
dc.subjectElectronic apex locatores
dc.subjectPreflaringes
dc.subjectRoot canal treatmentes
dc.subjectWorking lengthes
dc.titleInfluence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysises
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.publisherversionhttps://www.mdpi.com/2077-0383/10/13/2760es
dc.identifier.doi10.3390/jcm10132760es
dc.journaltitleJournal of Clinical Medicinees
dc.publication.volumen10es
dc.publication.issue3es
dc.publication.initialPage2760es

FicherosTamañoFormatoVerDescripción
Influence of Coronal...pdf27.13MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional