Mostrar el registro sencillo del ítem

Artículo

dc.creatorEnamorado Báez, Santiago Migueles
dc.creatorHurtado, María Doloreses
dc.creatorAndreu Cáceres, Luises
dc.creatorMartínez, Franciscoes
dc.creatorSánchez, Josées
dc.creatorAbril Hernández, José Maríaes
dc.date.accessioned2022-10-21T11:00:53Z
dc.date.available2022-10-21T11:00:53Z
dc.date.issued2007
dc.identifier.citationEnamorado Báez, S.M., Hurtado, M.D., Andreu Cáceres, L., Martínez, F., Sánchez, J. y Abril Hernández, J.M. (2007). Development of a recording water flow meter using ultrasonic measurement of water levels in a slotted U-pipe. Agricultural Water Management, 88 (1-3), 263-268. https://doi.org/10.1016/j.agwat.2006.10.003.
dc.identifier.issn0378-3774es
dc.identifier.urihttps://hdl.handle.net/11441/138230
dc.description.abstractThe accurate measurement and recording of water flow rates is necessary in the perfor-mance of field experiments in irrigation, overland flow or drainage studies. There is a lack of reliable, low-cost commercial flow meters that are able to operate under ‘‘non-pressure’’ conditions. This work describes a simply designed recording meter based on the ultrasonic measurement of water levels in a slotted U-pipe. A three-width slot design allows accurate flow measurements in the range 0–3 L s 1 and the ultrasonic probe allows for high resolu-tion measurements. Six replications of the instrument have been performed and calibrated (water levels against water flows) in laboratory experiments. After that, they have been successfully tested under field conditions, monitoring water flows which were recorded by using a data logger in the drainage system of an experimental farm in southwest Spain during several irrigation episodes in summer 2005.es
dc.description.sponsorshipJunta de Andalucía IFAPA-C03-029es
dc.formatapplication/pdfes
dc.format.extent6es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofAgricultural Water Management, 88 (1-3), 263-268.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFlow meteres
dc.subjectFlow recordinges
dc.subjectDrainage waterses
dc.titleDevelopment of a recording water flow meter using ultrasonic measurement of water levels in a slotted U-pipees
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/submittedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Aplicada Ies
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ciencias Agroforestaleses
dc.relation.projectIDIFAPA-C03-029es
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0378377406002563?via%3Dihubes
dc.identifier.doi10.1016/j.agwat.2006.10.003es
dc.journaltitleAgricultural Water Managementes
dc.publication.volumen88es
dc.publication.issue1-3es
dc.publication.initialPage263es
dc.publication.endPage268es
dc.contributor.funderJunta de Andalucíaes

FicherosTamañoFormatoVerDescripción
1-s2.0-S0378377406002563-main.pdf776.9KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional