dc.creator | Enamorado Báez, Santiago Miguel | es |
dc.creator | Hurtado, María Dolores | es |
dc.creator | Andreu Cáceres, Luis | es |
dc.creator | Martínez, Francisco | es |
dc.creator | Sánchez, José | es |
dc.creator | Abril Hernández, José María | es |
dc.date.accessioned | 2022-10-21T11:00:53Z | |
dc.date.available | 2022-10-21T11:00:53Z | |
dc.date.issued | 2007 | |
dc.identifier.citation | Enamorado Báez, S.M., Hurtado, M.D., Andreu Cáceres, L., Martínez, F., Sánchez, J. y Abril Hernández, J.M. (2007). Development of a recording water flow meter using ultrasonic measurement of water levels in a slotted U-pipe. Agricultural Water Management, 88 (1-3), 263-268. https://doi.org/10.1016/j.agwat.2006.10.003. | |
dc.identifier.issn | 0378-3774 | es |
dc.identifier.uri | https://hdl.handle.net/11441/138230 | |
dc.description.abstract | The accurate measurement and recording of water flow rates is necessary in the perfor-mance of field
experiments in irrigation, overland flow or drainage studies. There is a lack of reliable, low-cost commercial
flow meters that are able to operate under ‘‘non-pressure’’ conditions. This work describes a simply designed
recording meter based on the ultrasonic measurement of water levels in a slotted U-pipe. A three-width slot
design allows accurate flow measurements in the range 0–3 L s
1
and the ultrasonic probe allows for high
resolu-tion measurements. Six replications of the instrument have been performed and calibrated (water
levels against water flows) in laboratory experiments. After that, they have been successfully tested under
field conditions, monitoring water flows which were recorded by using a data logger in the drainage system
of an experimental farm in southwest Spain during several irrigation episodes in summer 2005. | es |
dc.description.sponsorship | Junta de Andalucía IFAPA-C03-029 | es |
dc.format | application/pdf | es |
dc.format.extent | 6 | es |
dc.language.iso | eng | es |
dc.publisher | Elsevier | es |
dc.relation.ispartof | Agricultural Water Management, 88 (1-3), 263-268. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Flow meter | es |
dc.subject | Flow recording | es |
dc.subject | Drainage waters | es |
dc.title | Development of a recording water flow meter using ultrasonic measurement of water levels in a slotted U-pipe | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/submittedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Aplicada I | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Ciencias Agroforestales | es |
dc.relation.projectID | IFAPA-C03-029 | es |
dc.relation.publisherversion | https://www.sciencedirect.com/science/article/pii/S0378377406002563?via%3Dihub | es |
dc.identifier.doi | 10.1016/j.agwat.2006.10.003 | es |
dc.journaltitle | Agricultural Water Management | es |
dc.publication.volumen | 88 | es |
dc.publication.issue | 1-3 | es |
dc.publication.initialPage | 263 | es |
dc.publication.endPage | 268 | es |
dc.contributor.funder | Junta de Andalucía | es |