Mostrar el registro sencillo del ítem

Trabajo Fin de Máster

dc.contributor.advisorJiménez-Castellanos Ballesteros, Emilioes
dc.contributor.advisorOrozco Varo, Anaes
dc.creatorRuiz Carrión, Claudiaes
dc.date.accessioned2022-10-17T13:53:41Z
dc.date.available2022-10-17T13:53:41Z
dc.date.issued2021-09
dc.identifier.citationRuiz Carrión, C. (2021). Medición de microgaps en prótesis sobre implantes. Una revisión bibliográfica. (Trabajo Fin de Máster Inédito). Universidad de Sevilla, Sevilla.
dc.identifier.urihttps://hdl.handle.net/11441/137964
dc.description.abstractIntroducción: los microgaps presentes en la conexión pilar-implante están presentes en todos los sistemas implantológicos. Estos defectos causan alteraciones por ser reservorio para microorganismos y por influir en el comportamiento mecánico del conjunto ya que causan micromovimientos. Ambas características perjudican a los tejidos periimplantarios promoviendo su inflamación y pérdida. Objetivos: analizar, mediante una revisión bibliográfica, los distintos métodos de medición que se emplean para evaluar el tamaño y el número de microgaps presentes en la conexión pilar-implante. Material y Método: se ha realizado una revisión bibliográfica desde enero de 2014 hasta junio de 2021 buscando detalladamente en PubMed, Scopus y Cochrane Oral Health Database. Se identificaron 20 artículos que cumplían los requisitos de inclusión. Resultados: para la visualización de los microgaps en la conexión pilar-implante existen 3 métodos: mediante el uso de microscopio electrónico de barrido que utiliza softwares externos para la medición de microgaps, empleando microtomografía computarizada y mediante radiografía de sincrotrón que ambos métodos utilizan el software del escáner para las mediciones. Conclusiones: en todas las estructuras implantoprotésicas formadas por dos componentes se han hallado microgaps en las conexiones pilar -implante para los que existen diversos métodos de medición, siendo las mediciones con microtomografía computarizada y con radiografía con sincrotrón las que dan una información más precisa.es
dc.description.abstractIntroduction: the microgaps present in the abutment-implant connection are found in all implant systems. These defects cause alterations by being a reservoir for microorganisms and by influencing the mechanical behavior of the assembly since they cause micro-movements. Both characteristics damage the peri-implant tissues promoting their inflammation and loss the implant. Objectives: to analyze, by means of a bibliographic review, the different measurement methods used to evaluate the size and number of microgaps present in the abutmentimplant connection. Material and Method: a bibliographic review was carried out from January 2014 to June 2021, searching in detail in PubMed, Scopus and Cochrane Oral Health Database. Twenty articles were identified that met the inclusion requirements. Results: for the visualization of the microgaps in the abutment-implant connection there are 3 methods: by using a scanning electron microscope that uses external software for the measurement of microgaps, using computerized microtomography and by synchrotron radiography that both methods use the software of the scanner for measurements. Conclusions: Microgaps have been found in the abutment-implant connections in all impalntoprosthetic structures made up of two components, for which there are various measurement methods, with computed microtomography and synchrotron radiography measurements that provide the most accurate informationes
dc.formatapplication/pdfes
dc.format.extent31 p.es
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMisfites
dc.subjectAbutment implant-prothesises
dc.subjectMeasurement micro gapes
dc.titleMedición de microgaps en prótesis sobre implantes. Una revisión bibliográficaes
dc.title.alternativeMicro-Gaps measurement in implant prosthesis. A bibliographic reviewes
dc.typeinfo:eu-repo/semantics/masterThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.description.degreeUniversidad de Sevilla. Máster Oficial en Odontología Restauradora Estética y Funcional.es
dc.publication.endPage25es

FicherosTamañoFormatoVerDescripción
TFM153-RUIZ CARRIÓN.pdf1.340MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional