dc.contributor.advisor | Serrera Figallo, María de los Ángeles | es |
dc.contributor.advisor | Castillo Oyagüe, Raquel | es |
dc.creator | Oliveros López, Luis Guillermo | es |
dc.date.accessioned | 2022-05-17T06:46:05Z | |
dc.date.available | 2022-05-17T06:46:05Z | |
dc.date.issued | 2022-03-18 | |
dc.identifier.citation | Oliveros López, L.G. (2022). Estudio de la pérdida de material óseo en pacientes con bruxismo e implantes dentales. (Tesis Doctoral Inédita). Universidad de Sevilla, Sevilla. | |
dc.identifier.uri | https://hdl.handle.net/11441/133374 | |
dc.description.abstract | El bruxismo es una actividad motora inconsciente, involuntaria y sostenida
que produce un rechinamiento excesivo de los dientes y/o un apretamiento de la
mandíbula que podríá afectar a los implantes y a las rehabilitaciones de los
pacientes.
La etiología exacta del bruxismo continúa sin determinar, pero se sabe que
involucra múltiples factores. La literatura carece de estudios sobre el posible efecto
de la morfología del implante sobre la resistencia de la interfaz hueso-implante
osteointegrado en presencia de bruxismo.
Nuestro objetivo fue evaluar la respuesta mecánica de la interfaz huesoimplante
en pacientes bruxistas cuyas prótesis implantológicas están sometidas a
una carga cíclica parafuncional durante un período simulado de 10 años.
Con este objetivo, comenzamos haciendo una revisión en la literatura para
investigar el "bruxismo" como condición y patología, y los "trastornos
temporomandibulares", ası́ como sus posibles correlaciones con la pérdida de hueso
marginal alrededor de los implantes dentales.
Como hipótesis nula, establecimos que tanto el implante M-12 como el Astra
presentarían niveles similares de pérdida ósea en la interfaz hueso-implante tras
una simulación de bruxismo de 10 años.
Por tanto, se realizó una comparación entre dos tipos de implantes (M-12 y
Astra) y se determinó el patrón de reabsorción ósea considerando el estado de
estrés y la pérdida de hueso cortical como criterios de evaluación. Se aplicaron
técnicas de simulación numérica basadas en el método de análisis de elementos
finitos en un análisis dinámico de las fuerzas recibidas, junto con un modelo
constitutivo de remodelación ó sea que altera las propiedades físicas del hueso.
La pérdida de superficie de hueso cortical simulada en el área del cuello del
implante fue un 8,6% mayor en el implante Astra que en el implante M-12. En
comparación con el implante M-12, el mayor estrés sostenido en el tiempo
observado en el implante Astra, junto con la mayor pérdida de superficie ósea
cortical registrada en su cuello, podrían ser factores predictivos de una mayor
probabilidad de fracaso de aquellas prótesis colocadas sobre implantes Astra en
pacientes bruxistas. | es |
dc.description.abstract | Bruxism is an unconscious, involuntary and sustained motor activity that
results in excessive teeth grinding and/or jaw clenching that could affect patients’
implants and rehabilitations.
The accurate aetiology for bruxism remains ascertained, but it is known to
involve multiple factors. The literature lacks studies on the possible effect of implant
morphology on the resistance of the bone-implant osseointegrated interface when
bruxism is present.
Our objective was to assess the mechanical response of the bone-implant
interface in bruxist patients whose implant prostheses are subjected to
parafunctional cyclic loading over a simulated period of 10 years.
With this objective, we started making a bibliographic revision about
‘bruxism’ as a condition and pathology, and ‘temporomandibular disorders’, as well
as about their possible correlations with the marginal bone loss around dental
implants.
As a null hypothesis, we established that both the M-12 and the Astra
implants would present similar levels of bone loss at the implant-bone interface
after a 10-year simulation of bruxism.
Therefore, a comparison was carried out between two types of implants (M-
12 and Astra Tech), and a pattern of bone loss was determined considering both the
stress state and the cortical bone surface loss as the evaluation criteria. Numerical
simulation techniques based on the finite element analysis method were applied in
a dynamic analysis of the received forces; together with a constitutive model of bone
remodelling that alters the physical properties of the bone.
The simulated cortical bone surface loss at the implant neck area was 8.6%
greater in the Astra implant than in the M-12 implant. Compared to the M-12
implant, the higher sustained stress observed over time in the Astra implant,
together with the greater cortical bone surface loss that occurred at its neck area,
may be related to a major probability of failure of those prostheses placed over Astra
implants in bruxist patients. | es |
dc.format | application/pdf | es |
dc.format.extent | 194 p. | es |
dc.language.iso | spa | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | Estudio de la pérdida de material óseo en pacientes con bruxismo e implantes dentales | es |
dc.type | info:eu-repo/semantics/doctoralThesis | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Estomatología | es |
dc.publication.endPage | 194 | es |