Mostrar el registro sencillo del ítem

Artículo

dc.creatorLozano, Pabloes
dc.creatorPeña, Martaes
dc.creatorHerrero Climent, Marianoes
dc.creatorRíos-Santos, J.V.es
dc.creatorRíos Carrasco, Blancaes
dc.creatorBrizuela, Aritzaes
dc.creatorGil, Javieres
dc.date.accessioned2022-03-17T15:02:35Z
dc.date.available2022-03-17T15:02:35Z
dc.date.issued2022-02-19
dc.identifier.citationLozano, P., Peña, M., Herrero-Climent, M., Ríos-Santos, J.V., Ríos Carrasco, B., Brizuela, A. y Gil, J. (2022). Corrosion Behavior of Titanium Dental Implants with Implantoplasty. Materials, 15 (4)
dc.identifier.issn1996-1944es
dc.identifier.urihttps://hdl.handle.net/11441/130964
dc.description.abstractThe procedure generally used to remove bacterial biofilm adhering to the surface of titanium on dental implants is implantoplasty. This treatment is based on the machining of the titanium surface to remove bacterial plaque. In this study, we used 60 grade 4 titanium implants and performed the implantoplasty protocol. Using X-ray diffraction, we determined the stresses accumulated in each of the as-received, machined and debris implants. The resistance to corrosion in open circuit and potentiodynamically in physiological medium has been determined, and the corrosion potentials and intensities have been determined. Tests have been carried out to determine ion release by ICP-MS at different immersion times. The results show that the corrosion resistance and the release of titanium ions into the medium are related to the accumulated energy or the degree of deformation. The titanium debris exhibit compressive residual stresses of −202 MPa, the implant treated with implantoplasty −120 MPa, and as-received −77 MPa, with their corrosion behavior resulting in corrosion rates of 0.501, 0.77, and 0.444 mm/year, respectively. Debris is the material with the worst corrosion resistance and the one that releases the most titanium ions to the physiological medium (15.3 ppb after 21 days vs. 7 ppb for as-received samples). Pitting has been observed on the surface of the debris released into the physiological environment. This behavior should be taken into account by clinicians for the good long-term behavior of implants with implantoplasty.es
dc.formatapplication/pdfes
dc.format.extent12 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofMaterials, 15 (4)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCorrosiones
dc.subjectTitanium ion releasees
dc.subjectImplantoplastyes
dc.subjectDebrises
dc.subjectResidual stresseses
dc.titleCorrosion Behavior of Titanium Dental Implants with Implantoplastyes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.publisherversionhttps://www.mdpi.com/1996-1944/15/4/1563es
dc.identifier.doi10.3390/ma15041563es
dc.journaltitleMaterialses
dc.publication.volumen15es
dc.publication.issue4es

FicherosTamañoFormatoVerDescripción
Corrosion Behavior.pdf2.963MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional