Mostrar el registro sencillo del ítem

Artículo

dc.creatorEfthymiou, Chrysanthies
dc.creatorBarmparesos, Nikolaoses
dc.creatorTasios, Panagiotis D.es
dc.creatorNtouros, Vasileioses
dc.creatorZoulis, Vasileioses
dc.creatorKarlessi, Theonies
dc.creatorSalmerón Lissén, José Manueles
dc.creatorAssimakopoulos, Maragarita Nikies
dc.date.accessioned2022-02-24T18:49:03Z
dc.date.available2022-02-24T18:49:03Z
dc.date.issued2021-10
dc.identifier.citationEfthymiou, C., Barmparesos, N., Tasios, .D., Ntouros, V., Zoulis, V., Karlessi, T.,...,Assimakopoulos, M.N. (2021). Indoor Environmental Quality Evaluation Strategy as an Upgrade (Renovation) Measure in a Historic Building Located in the Mediterranean Zone (Athens, Greece). Applied Sciences, 11 (21), 10133.
dc.identifier.issnEISSN 2076-3417es
dc.identifier.urihttps://hdl.handle.net/11441/130215
dc.description.abstractThe assessment of indoor environmental quality in historic buildings converted to museums is a significant tool in deep energy renovation processes, as it provides insights for the microclimatic conditions in the interiors of the building where vast numbers of visitors walk every year and where artifacts that are vulnerable to pollution are exhibited. In this work, aiming to contribute to the development of an energy retrofitting protocol applied in the Mediterranean region (HAPPEN MedZeb protocol) for museums hosted in historic buildings by providing useful data, an experimental campaign to evaluate the indoor environmental quality of a museum housed in a historic building located in Athens took place from February 2019 to April 2021 and was divided into two periods. The findings revealed high concentrations of volatile organic compounds as well as poor thermal comfort levels since the sensors recorded low acceptable percentages of T values within the limits from 7 to 33% for the entire experimental period. Based on the findings, recommendations for retrofitting interventions are made.es
dc.description.sponsorshipUnión Europea 785072es
dc.formatapplication/pdfes
dc.format.extent17 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofApplied Sciences, 11 (21), 10133.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIndoor environmental qualityes
dc.subjectHistoric buildingses
dc.subjectMuseumses
dc.subjectRetrofit protocoles
dc.subjectMediterranean zonees
dc.subjectHAPPEN projectes
dc.titleIndoor Environmental Quality Evaluation Strategy as an Upgrade (Renovation) Measure in a Historic Building Located in the Mediterranean Zone (Athens, Greece)es
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Energéticaes
dc.relation.projectID785072es
dc.relation.publisherversionhttps://doi.org/10.3390/app112110133es
dc.identifier.doi10.3390/app112110133es
dc.contributor.groupUniversidad de Sevilla. TEP143: Termotecniaes
dc.journaltitleApplied Scienceses
dc.publication.volumen11es
dc.publication.issue21es
dc.publication.initialPage10133es
dc.contributor.funderEuropean Commission (EC)es

FicherosTamañoFormatoVerDescripción