dc.creatorPérez Bartolomé, Franciscoes
dc.creatorRocha de Lossada, Carloses
dc.creatorSánchez González, José Maríaes
dc.creatorFeu Basilio, Silviaes
dc.creatorTorras Sanvicens, Josepes
dc.creatorPeraza Nieves, Jorgees
dc.date.accessioned2022-01-24T11:23:08Z
dc.date.available2022-01-24T11:23:08Z
dc.date.issued2021
dc.identifier.citationPérez Bartolomé, F., Rocha de Lossada, C., Sánchez González, J.M., Feu Basilio, S., Torras Sanvicens, J. y Peraza Nieves, J. (2021). Anterior-Segment Swept-Source Ocular Coherence Tomography and Scheimpflug Imaging Agreement for Keratometry and Pupil Measurements in Healthy Eyes. Journal of Clinical Medicine, 10 (24), 5789.
dc.identifier.issn2077-0383es
dc.identifier.urihttps://hdl.handle.net/11441/129118
dc.description.abstractThis study examines agreement between the devices Anterion® and Pentacam HR® used for corneal and pupil measurements in healthy eyes. The parameters compared between the two devices were: anterior Km (D), anterior K2 (D), anterior K1 (D), anterior K1 axis (°), anterior astigmatism (D), anterior K max (D), posterior Km (D), posterior K2 (D), posterior K1 (D), posterior K1 axis (°), posterior astigmatism (D), CCT (µm), thinnest point thickness (µm), thinnest point X-coordinate (mm), thinnest point Y-coordinate (mm), pupil diameter (mm), pupil center-corneal vertex distance (mm) (angle kappa), pupil centroid angle (°), pupil centroid X-coordinate (mm), and pupil centroid Y-coordinate (mm). The Student’s t test for independent samples identified significant differences (p < 0.005) between devices for the measurements anterior and posterior flat K axis, posterior flat K, steep K, and mean K. For these last three measurements, although significant, none of the differences were clinically relevant. Corneal power and thickness measurements except Kf axis showed excellent agreement between Anterion and Pentacam. In a clinical setting we would not recommend the interchangeable use of Pentacam and Anterion for measurement of pupil parameters.es
dc.formatapplication/pdfes
dc.format.extent9 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofJournal of Clinical Medicine, 10 (24), 5789.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectanterior-segment swept-sourcees
dc.subjectocular coherence tomographyes
dc.subjectScheimpflug imaginges
dc.subjectagreement analysises
dc.subjectpupil measurementses
dc.titleAnterior-Segment Swept-Source Ocular Coherence Tomography and Scheimpflug Imaging Agreement for Keratometry and Pupil Measurements in Healthy Eyeses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.relation.publisherversionhttps://doi.org/10.3390/jcm10245789es
dc.identifier.doi10.3390/jcm10245789es
dc.journaltitleJournal of Clinical Medicinees
dc.publication.volumen10es
dc.publication.issue24es
dc.publication.initialPage5789es