Mostrar el registro sencillo del ítem

Ponencia

dc.creatorAcha Piñero, Begoñaes
dc.creatorSerrano Gotarredona, María del Carmenes
dc.creatorRangayyan, Rangaraj M.es
dc.creatorLeo Desautels, J. E.es
dc.date.accessioned2022-01-14T09:08:39Z
dc.date.available2022-01-14T09:08:39Z
dc.date.issued2009
dc.identifier.citationAcha Piñero, B., Serrano Gotarredona, M.d.C., Rangayyan, R.M. y Leo Desautels, J.E. (2009). Detection of microcalcifications in mammograms using error of prediction and statistical measures. En Simposium Nacional de la Unión Científica Internacional de Radio (013011-1-013011-10), Santiago de Compostela, España: Society of Photo-optical Instrumentation Engineers.
dc.identifier.issn1017-9909es
dc.identifier.urihttps://hdl.handle.net/11441/128843
dc.description.abstractA two-stage method for detecting microcalcifications in mammograms is presented. In the first stage, the determination of the candidates for microcalcifications is performed. For this purpose, a 2-D linear prediction error filter is applied, and for those pixels where the prediction error is larger than a threshold, a statistical measure is calculated to determine whether they are candidates for microcalcifications or not. In the second stage, a feature vector is derived for each candidate, and after a classification step using a support vector machine, the final detection is performed. The algorithm is tested with 40 mammographic images, from Screen Test: The Alberta Program for the Early Detection of Breast Cancer with 50- m resolution, and the results are evaluated using a freeresponse receiver operating characteristics curve. Two different analyses are performed: an individual microcalcification detection analysis and a cluster analysis. In the analysis of individual microcalcifications, detection sensitivity values of 0.75 and 0.81 are obtained at 2.6 and 6.2 false positives per image, on the average, respectively. The best performance is characterized by a sensitivity of 0.89, a specificity of 0.99, and a positive predictive value of 0.79. In cluster analysis, a sensitivity value of 0.97 is obtained at 1.77 false positives per image, and a value of 0.90 is achieved at 0.94 false positive per imagees
dc.description.sponsorshipMinisterio de Sanidad FIS05-2028es
dc.formatapplication/pdfes
dc.format.extent10 p.es
dc.language.isospaes
dc.publisherSociety of Photo-optical Instrumentation Engineerses
dc.relation.ispartofSimposium Nacional de la Unión Científica Internacional de Radio (2009), pp. 013011-1-013011-10.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectDetectiones
dc.subjectMicrocalcificationses
dc.subjectMammogramses
dc.titleDetection of microcalcifications in mammograms using error of prediction and statistical measureses
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Teoría de la Señal y Comunicacioneses
dc.relation.projectIDFIS05-2028es
dc.relation.publisherversionhttps://opticalengineering.spiedigitallibrary.org/journals/journal-of-electronic-imaging/volume-18/issue-01/013011/Detection-of-microcalcifications-in-mammograms-using-error-of-prediction-and/10.1117/1.3099710.full?SSO=1es
dc.identifier.doi10.1117/1.3099710es
dc.publication.initialPage013011-1es
dc.publication.endPage013011-10es
dc.eventtitleSimposium Nacional de la Unión Científica Internacional de Radioes
dc.eventinstitutionSantiago de Compostela, Españaes
dc.identifier.sisius5460123es