dc.creator | Amaducci, Simone | es |
dc.creator | Aberle, Oliver | es |
dc.creator | Andrzejewski, J. | es |
dc.creator | Audouin, Laurent | es |
dc.creator | Bacak, M. | es |
dc.creator | Balibrea, J. | es |
dc.creator | Cortés Giraldo, Miguel Antonio | es |
dc.creator | Guerrero Sánchez, Carlos | es |
dc.creator | Lerendegui Marco, Jorge | es |
dc.creator | Quesada Molina, José Manuel | es |
dc.creator | Sabaté Gilarte, Marta | es |
dc.creator | Žugec, P. | es |
dc.date.accessioned | 2021-05-24T17:09:18Z | |
dc.date.available | 2021-05-24T17:09:18Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | Amaducci, S., Aberle, O., Andrzejewski, J., Audouin, L., Bacak, M., Balibrea, J.,...,Žugec, P. (2020). Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy. EPJ Web of Conferences, 239, 08002. | |
dc.identifier.issn | 2100-014X | es |
dc.identifier.uri | https://hdl.handle.net/11441/109269 | |
dc.description.abstract | An accurate measurement of the 235U(n,f) cross section from thermal to 170 keV of neutron energy has recently been performed at n_TOF facility at CERN using 6Li(n,t)4He and 10B(n,α)7Li as references. This measurement has been carried out in order to investigate a possible overestimation of the 235U fission cross section evaluation provided by most recent libraries between 10 and 30 keV. A custom experimental apparatus based on in-beam silicon detectors has been used, and a Monte Carlo simulation in GEANT4 has been employed to characterize the setup and calculate detectors efficiency. The results evidenced the presence of an overestimation in the interval between 9 and 18 keV and the new data may be used to decrease the uncertainty of 235U(n,f) cross section in the keV region. | es |
dc.format | application/pdf | es |
dc.format.extent | 5 p. | es |
dc.language.iso | eng | es |
dc.publisher | EDP Sciences | es |
dc.relation.ispartof | EPJ Web of Conferences, 239, 08002. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Atómica, Molecular y Nuclear | es |
dc.relation.publisherversion | https://doi.org/10.1051/epjconf/202023908002 | es |
dc.identifier.doi | 10.1051/epjconf/202023908002 | es |
dc.journaltitle | EPJ Web of Conferences | es |
dc.publication.volumen | 239 | es |
dc.publication.initialPage | 08002 | es |