Mostrar el registro sencillo del ítem

Artículo

dc.creatorAmaducci, Simonees
dc.creatorAberle, Oliveres
dc.creatorAndrzejewski, J.es
dc.creatorAudouin, Laurentes
dc.creatorBacak, M.es
dc.creatorBalibrea, J.es
dc.creatorCortés Giraldo, Miguel Antonioes
dc.creatorGuerrero Sánchez, Carloses
dc.creatorLerendegui Marco, Jorgees
dc.creatorQuesada Molina, José Manueles
dc.creatorSabaté Gilarte, Martaes
dc.creatorŽugec, P.es
dc.date.accessioned2021-05-24T17:09:18Z
dc.date.available2021-05-24T17:09:18Z
dc.date.issued2020
dc.identifier.citationAmaducci, S., Aberle, O., Andrzejewski, J., Audouin, L., Bacak, M., Balibrea, J.,...,Žugec, P. (2020). Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy. EPJ Web of Conferences, 239, 08002.
dc.identifier.issn2100-014Xes
dc.identifier.urihttps://hdl.handle.net/11441/109269
dc.description.abstractAn accurate measurement of the 235U(n,f) cross section from thermal to 170 keV of neutron energy has recently been performed at n_TOF facility at CERN using 6Li(n,t)4He and 10B(n,α)7Li as references. This measurement has been carried out in order to investigate a possible overestimation of the 235U fission cross section evaluation provided by most recent libraries between 10 and 30 keV. A custom experimental apparatus based on in-beam silicon detectors has been used, and a Monte Carlo simulation in GEANT4 has been employed to characterize the setup and calculate detectors efficiency. The results evidenced the presence of an overestimation in the interval between 9 and 18 keV and the new data may be used to decrease the uncertainty of 235U(n,f) cross section in the keV region.es
dc.formatapplication/pdfes
dc.format.extent5 p.es
dc.language.isoenges
dc.publisherEDP Scienceses
dc.relation.ispartofEPJ Web of Conferences, 239, 08002.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleAccurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energyes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.relation.publisherversionhttps://doi.org/10.1051/epjconf/202023908002es
dc.identifier.doi10.1051/epjconf/202023908002es
dc.journaltitleEPJ Web of Conferenceses
dc.publication.volumen239es
dc.publication.initialPage08002es

FicherosTamañoFormatoVerDescripción
Accurate measurement of the ...781.3KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional