dc.description.abstractThe distribution of temperature on a Solar Power Tower (SPT) plant receiver directly affects the lifespan of the structure and energy generated by the plant. Temperature peaks and uneven distributions can be caused by the aiming strategy enforced on the heliostat field. A non-optimised aiming strategy can lead to suboptimal energy generation and, more importantly, to risk of permanent damage to receiver components from thermal overloading due to sharp flux gradients. In order to reduce damage to receivers and optimise the energy generation, an aiming strategy is developed which homogenises the flux distribution on a flat plate receiver in a SPT plant. Results of a near real-time optimised aiming strategy are presented, demonstrating applicability to SPT plants of any size and shape, whilst also considering inclement weather conditions.es
dc.formatapplication/pdfes
dc.format.extent6 p.es
dc.language.isoenges
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDes
dc.relation.ispartofEnergy, 137, 285-291.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectSolar thermal poweres
dc.subjectAiming strategyes
dc.subjectInteger programminges
dc.titleOptimisation of aiming strategies in Solar Power Tower plantses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estadística e Investigación Operativaes
dc.relation.publisherversionhttp://doi.org/10.1016/j.energy.2017.06.163es
dc.identifier.doi10.1016/j.energy.2017.06.163es
dc.contributor.groupUniversidad de Sevilla. FQM329: Optimizaciónes
dc.journaltitleEnergyes
dc.publication.volumen137es
dc.publication.initialPage285es
dc.publication.endPage291es

FicherosTamañoFormatoVerDescripción
Optimisation of aiming strategies ...2.905MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional