Mostrar el registro sencillo del ítem

Artículo

dc.creatorMontero Miralles, Palomaes
dc.creatorCastillo-Oyagüe, Raqueles
dc.creatorSaéz de la Fuente, Isabeles
dc.creatorLynch, Christopher D.es
dc.creatorCastillo-Dalí, Gabrieles
dc.creatorTorres-Lagares, Danieles
dc.date.accessioned2021-03-17T18:24:03Z
dc.date.available2021-03-17T18:24:03Z
dc.date.issued2014
dc.identifier.citationMontero Miralles, P., Castillo-Oyagüe, R., Saéz de la Fuente, I., Lynch, C.D., Castillo-Dalí, G. y Torres-Lagares, D. (2014). Effect of the Nd:YAG laser on sealer penetration into root canal surfaces: a confocal microscope analysis. Journal of Dentistry, 42 (6), 753-759.
dc.identifier.issn0300-5712es
dc.identifier.urihttps://hdl.handle.net/11441/106217
dc.description.abstractObjectives: The objective of this in vitro study was to evaluate the use of the Neodymium:Yttrium-Aluminium-Garnet (Nd:YAG) laser as part of the root canal treatment on the penetration of sealer into dentinal tubules. Methods: Eighty extracted lower premolars were randomly assigned to two groups (n = 40 each): Control group (CG), subjected to a conventional protocol of endodontic instrumentation and obturation; and Laser group (LG), in which Nd:YAG laser irradiations were combined with conventional preparation and obturation. Endodonted samples were sectioned at 3 and 5 mm from the apex and observed under a confocal scanning microscope (CLSM). The penetration depth into the dentinal tubules and the extension of the intracanal perimeter infiltrated by sealer were measured. The Student-Newman Keuls test was run for between-group comparisons (α=.05). Results: The depth of sealer penetration into dentinal tubules did not differ among groups. LG samples showed the significantly highest percentage of penetrated perimeter at 3 mm from the root apex. Within each group, the greatest depth of penetration (P=.0001), and the major percentage of penetrated perimeter (P <.001), were recorded at 5 mm. Conclusions: The application of the Nd:YAG laser after instrumentation did not improve the depth of sealer penetration into the dentinal tubules. The laser enlarged the total penetrable perimeter near the apexes
dc.formatapplication/pdfes
dc.format.extent6es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofJournal of Dentistry, 42 (6), 753-759.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectConfocal microscopees
dc.subjectNd:YAG laseres
dc.subjectEndodontic instrumentationes
dc.subjectDentinal permeabilityes
dc.subjectEndodontic sealeres
dc.subjectSealer penetrationes
dc.titleEffect of the Nd:YAG laser on sealer penetration into root canal surfaces: a confocal microscope analysises
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.journaltitleJournal of Dentistryes
dc.publication.volumen42es
dc.publication.issue6es
dc.publication.initialPage753es
dc.publication.endPage759es

FicherosTamañoFormatoVerDescripción
J Dent Laser.pdf211.9KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional