dc.identifier.citationGalán-Marín, C., Rivera-Gómez, C., López Cabeza, V.P. y Roa Fernández, J. (2018). Courtyard microclimate ENVI-met outputs deviation from the experimental data. Building and Environment, 144, 129-141.
dc.identifier.issn0360-1323es
dc.identifier.issn1873-684Xes
dc.identifier.urihttps://hdl.handle.net/11441/104276
dc.description.abstractIt is necessary to determine if the tools used in the process of building performance calculation accurately reflect the real conditions, with the objective of introducing simulation in the design process of buildings. The aim of this study is the assessment of the effectiveness of the software ENVI-met v4 on the prediction of the thermodynamic performance of courtyards by means of comparing between field data obtained from simultaneous monitoring of three courtyards and the results obtained from the software simulations. The results of the study show a significant difference between monitored and simulated data for air temperature inside the courtyards. And the difference between outdoor temperature and courtyard temperature is too important not to be considered in building efficiency calculations. For that reason, ENVI-met it is not an accurate software to be used in the process of design of this kind of architectural transitional spaces that can be very important in order to design nZEB in some climates.es
dc.formatapplication/pdfes
dc.format.extent16 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofBuilding and Environment, 144, 129-141.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectInner courtyardses
dc.subjectPatioes
dc.subjectSimulationes
dc.subjectENVI-metes
dc.subjectMediterranean climatees
dc.subjectClima mediterráneoes
dc.subjectSimulaciónes
dc.titleCourtyard microclimate ENVI-met outputs deviation from the experimental dataes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas I (ETSA)es
dc.relation.publisherversionhttps://doi.org/10.1016/j.buildenv.2018.08.013es
dc.identifier.doi10.1016/j.buildenv.2018.08.013es
dc.journaltitleBuilding and Environmentes
dc.publication.volumen144es
dc.publication.initialPage129es
dc.publication.endPage141es

FicherosTamañoFormatoVerDescripción
Courtyard microclimate ENVI-met ...4.343MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional