Mostrar el registro sencillo del ítem

Artículo

dc.creatorPancin, Julienes
dc.creatorFernández Martínez, Begoñaes
dc.creatorDamoy, S.es
dc.creatorKebbiri, Mariames
dc.creatorPapaevangelou, Thomases
dc.creatorRiallot, Marces
dc.date.accessioned2021-01-20T15:26:42Z
dc.date.available2021-01-20T15:26:42Z
dc.date.issued2012
dc.identifier.citationPancin, J., Fernández Martínez, B., Damoy, S., Kebbiri, M., Papaevangelou, T. y Riallot, M. (2012). Micromegas at low pressure for beam tracking. Journal of Instrumentation, 7 (3), C03017.
dc.identifier.issn1748-0221es
dc.identifier.urihttps://hdl.handle.net/11441/103984
dc.description.abstractNew facilities like FAIR at GSI or SPIRAL2 at GANIL, will provide radioactive ion beams at low energies (less than 10 MeV/n). Such beams have generally a large emittance, which requires the use of beam tracking detectors to reconstruct the exact trajectories of the nuclei. To avoid the angular and energy straggling that classical beam tracking detectors would generate in the beam due to their thickness, we propose the use of SED (Secondary Electron Detectors). It consists of a low pressure gaseous detector placed outside the beam coupled to an emissive foil in the beam. Since 2008, different low pressure gaseous detectors (wire chambers and micromegas) have been constructed and tested. The performances achievable at low pressure are similar to or even better than the ones at atmospheric pressure. The fast charge collection leads to excellent timing properties as well as high counting rate capabilities. Several micromegas at low pressure were tested in the laboratory demonstrating a good time resolution, 13030 ps, which is compatible with the results obtained with wire chambers.es
dc.description.sponsorshipGobierno de España FPA2009-08848es
dc.formatapplication/pdfes
dc.format.extent9 p.es
dc.language.isoenges
dc.publisherInstitute of Physics Publishinges
dc.relation.ispartofJournal of Instrumentation, 7 (3), C03017.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMicropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc)es
dc.subjectParticle tracking detectors (Gaseous detectors)es
dc.titleMicromegas at low pressure for beam trackinges
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.relation.projectIDFPA2009-08848es
dc.relation.publisherversionhttp://dx.doi.org/10.1088/1748-0221/7/03/C03017es
dc.identifier.doi10.1088/1748-0221/7/03/C03017es
dc.journaltitleJournal of Instrumentationes
dc.publication.volumen7es
dc.publication.issue3es
dc.publication.initialPageC03017es

FicherosTamañoFormatoVerDescripción
Micromegas at low pressure.pdf130.1KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional