Mostrar el registro sencillo del ítem

Artículo

dc.creatorAcosta, M.N.es
dc.creatorAdiyabazar, C.es
dc.creatorGonzález - Longatt, F.es
dc.creatorAndrade, M.A.es
dc.creatorTorres, J.R.es
dc.creatorVazquez, E.es
dc.creatorRiquelme Santos, Jesús Manueles
dc.date.accessioned2020-12-01T14:45:30Z
dc.date.available2020-12-01T14:45:30Z
dc.date.issued2020
dc.identifier.citationAcosta, M.N., Adiyabazar, C., González - Longatt, F., Andrade, M.A., Torres, J.R., Vazquez, E. y Riquelme Santos, J.M. (2020). Optimal Under-Frequency Load Shedding Setting at Altai-Uliastai Regional Power System, Mongolia. Energies, 13 (5390), 1-18.
dc.identifier.issn1996-1073es
dc.identifier.urihttps://hdl.handle.net/11441/102880
dc.description.abstractThe Altai-Uliastai regional power system (AURPS) is a regional power system radially interconnected to the power system of Mongolia. The 110 kV interconnection is exceptionally long and susceptible to frequent trips because of weather conditions. The load-rich and low-inertia AURPS must be islanded during interconnection outages, and the under-frequency load shedding (UFLS) scheme must act to ensure secure operation. Traditional UFLS over-sheds local demand, negatively affecting the local population, especially during the cold Mongolian winter season. This research paper proposes a novel methodology to optimally calculate the settings of the UFLS scheme, where each parameter of the scheme is individually adjusted to minimise the total amount of disconnected load. This paper presents a computationally efficient methodology that is illustrated in a specially created co-simulation environment (DIgSILENT® PowerFactoryTM + Python). The results demonstrate an outstanding performance of the proposed approach when compared with the traditional one.es
dc.formatapplication/pdfes
dc.format.extent18es
dc.language.isoenges
dc.publisherMDPI AGes
dc.relation.ispartofEnergies, 13 (5390), 1-18.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFrequency controles
dc.subjectImproved harmony searches
dc.subjectMetaheuristic algorithmes
dc.subjectMongolian power systemes
dc.subjectOptimisationes
dc.subjectUnder-frequency load sheddinges
dc.titleOptimal Under-Frequency Load Shedding Setting at Altai-Uliastai Regional Power System, Mongoliaes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Eléctricaes
dc.relation.publisherversionhttps://www.mdpi.com/1996-1073/13/20/5390?type=check_update&version=1es
dc.identifier.doi10.3390/en13205390es
dc.contributor.groupUniversidad de Sevilla. TEP-196: Sistemas de Energía Eléctricaes
dc.journaltitleEnergieses
dc.publication.volumen13es
dc.publication.issue5390es
dc.publication.initialPage1es
dc.publication.endPage18es
dc.contributor.funderUniversidad Autónoma de Nuevo Leónes
dc.contributor.funderCONACYT - Consejo Nacional de Ciencia y Tecnología (México)es
dc.contributor.funderUniversidad del Sudeste de Noruegaes

FicherosTamañoFormatoVerDescripción
Optimal Under-Frequency .pdf3.053MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional