dc.description.abstractA mobile luminescent probe has been developed to detect fast ion losses and suprathermal ions escaping from the plasma of the TJ-II stellarator device. The priorities for its design have been flexibility for probe positioning, ease of maintenance, and detector sensitivity. It employs a coherent fiber bundle to relay, to the outside of the vacuum chamber, ionoluminescence images produced by the ions that impinge, after entering the detector head through a pinhole aperture, onto a screen of luminescent material. Ionoluminescence light detection is accomplished by a charge-coupled device camera and by a photomultiplier, both of which are optically coupled to the in-vacuum fiber bundle head by means of a standard optical setup. A detailed description of the detector, and the first results obtained when operated close to the plasma edge, are reported.es
dc.description.sponsorshipMinisterio de Educación y Ciencia FTN 2003-0905, ENE2007-65007es
dc.formatapplication/pdfes
dc.format.extent10 p.es
dc.language.isoenges
dc.publisherAIP Publishinges
dc.relation.ispartofReview of Scientific Instruments, 79 (9), 093511-1-093511-9.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleA flexible luminescent probe to monitor fast ion losses at the edge of the TJ-II stellaratores
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.relation.projectIDFTN 2003-0905es
dc.relation.projectIDENE2007-65007es
dc.relation.publisherversionhttp://dx.doi.org/10.1063/1.2979013es
dc.identifier.doi10.1063/1.2979013es
dc.contributor.groupUniversidad de Sevilla. RNM138: Física Nuclear Aplicadaes
dc.journaltitleReview of Scientific Instrumentses
dc.publication.volumen79es
dc.publication.issue9es
dc.publication.initialPage093511-1es
dc.publication.endPage093511-9es

FicherosTamañoFormatoVerDescripción
1.2979013.pdf1.861MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional