dc.creator | Jiménez Rey, D. | es |
dc.creator | Zurro, B. | es |
dc.creator | Guasp, P. | es |
dc.creator | Liniers, M. | es |
dc.creator | Baciero, A. | es |
dc.creator | García Muñoz, Manuel | es |
dc.date.accessioned | 2020-08-31T15:44:15Z | |
dc.date.available | 2020-08-31T15:44:15Z | |
dc.date.issued | 2008-09 | |
dc.identifier.citation | Jiménez Rey, D., Zurro, B., Guasp, P., Liniers, M., Baciero, A. y García Muñoz, M. (2008). A flexible luminescent probe to monitor fast ion losses at the edge of the TJ-II stellarator. Review of Scientific Instruments, 79 (9), 093511-1-093511-9. | |
dc.identifier.issn | 0034-6748 | es |
dc.identifier.uri | https://hdl.handle.net/11441/100577 | |
dc.description.abstract | A mobile luminescent probe has been developed to detect fast ion losses and suprathermal ions
escaping from the plasma of the TJ-II stellarator device. The priorities for its design have been
flexibility for probe positioning, ease of maintenance, and detector sensitivity. It employs a coherent
fiber bundle to relay, to the outside of the vacuum chamber, ionoluminescence images produced by the ions that impinge, after entering the detector head through a pinhole aperture, onto a screen of luminescent material. Ionoluminescence light detection is accomplished by a charge-coupled device camera and by a photomultiplier, both of which are optically coupled to the in-vacuum fiber bundle head by means of a standard optical setup. A detailed description of the detector, and the first results obtained when operated close to the plasma edge, are reported. | es |
dc.description.sponsorship | Ministerio de Educación y Ciencia FTN 2003-0905, ENE2007-65007 | es |
dc.format | application/pdf | es |
dc.format.extent | 10 p. | es |
dc.language.iso | eng | es |
dc.publisher | AIP Publishing | es |
dc.relation.ispartof | Review of Scientific Instruments, 79 (9), 093511-1-093511-9. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | A flexible luminescent probe to monitor fast ion losses at the edge of the TJ-II stellarator | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Atómica, Molecular y Nuclear | es |
dc.relation.projectID | FTN 2003-0905 | es |
dc.relation.projectID | ENE2007-65007 | es |
dc.relation.publisherversion | http://dx.doi.org/10.1063/1.2979013 | es |
dc.identifier.doi | 10.1063/1.2979013 | es |
dc.contributor.group | Universidad de Sevilla. RNM138: Física Nuclear Aplicada | es |
dc.journaltitle | Review of Scientific Instruments | es |
dc.publication.volumen | 79 | es |
dc.publication.issue | 9 | es |
dc.publication.initialPage | 093511-1 | es |
dc.publication.endPage | 093511-9 | es |