Mostrar el registro sencillo del ítem

Artículo

dc.creatorCuruia, M.es
dc.creatorCraciunescu, T.es
dc.creatorSoare, S.es
dc.creatorZoita, V.es
dc.creatorBraic, V.es
dc.creatorJet Contributorses
dc.creatorGarcía Muñoz, Manueles
dc.date.accessioned2020-07-31T09:22:13Z
dc.date.available2020-07-31T09:22:13Z
dc.date.issued2017-11
dc.identifier.citationCuruia, M., Craciunescu, T., Soare, S., Zoita, V., Braic, V., Jet Contributors, y García Muñoz, M. (2017). Upgrade of the tangential gamma-ray spectrometer beam-line for JET DT experiments. Fusion Engineering and Design, 123, 749-753.
dc.identifier.issn0920-3796es
dc.identifier.urihttps://hdl.handle.net/11441/100024
dc.description.abstractThe JET tangential gamma-ray spectrometer is undergoing an extensive upgrade in order to make itcompatible with the forthcoming deuterium-tritium (DT) experiments. The paper presents the resultsof the design for the main components for the upgrade of the spectrometer beam-line: tandem collima-tors, gamma-ray shields, and neutron attenuators. The existing tandem collimators will be upgraded byinstalling two additional collimator modules. Two gamma-ray shields will define the gamma-ray field-of-view at the detector end of the spectrometer line-of-sight. A set of three lithium hydride neutronattenuators will be used to control the level of the fast neutron flux on the gamma-ray detector. Thedesign of the upgraded spectrometer beam-line has been supported by extensive radiation (neutron andphoton) transport calculations using both large volume and point radiation sources.es
dc.description.sponsorshipEURATOM 633053es
dc.formatapplication/pdfes
dc.format.extent5 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofFusion Engineering and Design, 123, 749-753.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTokamakes
dc.subjectDiagnosticses
dc.subjectGamma-rayses
dc.subjectGamma-ray spectrometeres
dc.subjectNeutron attenuatorses
dc.titleUpgrade of the tangential gamma-ray spectrometer beam-line for JET DT experimentses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.relation.projectID633053es
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.fusengdes.2017.05.064es
dc.identifier.doi10.1016/j.fusengdes.2017.05.064es
dc.contributor.groupUniversidad de Sevilla. RNM138: Física Nuclear Aplicadaes
dc.journaltitleFusion Engineering and Designes
dc.publication.volumen123es
dc.publication.initialPage749es
dc.publication.endPage753es

FicherosTamañoFormatoVerDescripción
1-s2.0-S0920379617306087-main.pdf1.766MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional