Por motivos de mantenimiento se ha deshabilitado el inicio de sesión temporalmente. Rogamos disculpen las molestias.
Artículo
First measurements of a scintillator-based fast-ion loss detector in reversed Ip/Bt at the ASDEX Upgrade tokamak
Autor/es | Hidalgo Salaverri, Javier
Rueda Rueda, José Galdón Quiroga, Joaquín Cano Megías, Pilar Viezzer, Eleonora García Domínguez, Javier Oyola Domínguez, Pablo Ayllón Guerola, Juan Manuel García Muñoz, Manuel Happel, T. |
Departamento | Universidad de Sevilla. Departamento de Ingeniería Mecánica y de Fabricación Universidad de Sevilla. Departamento de Física Atómica, Molecular y Nuclear |
Fecha de publicación | 2023-08 |
Fecha de depósito | 2023-05-09 |
Publicado en |
|
Resumen | Fast-α losses in future fusion power plants are expected to follow the co- and counter-current directions due to the isotropy of the fusion reaction. At the ASDEX Upgrade tokamak, the co-current direction (achieved with ... Fast-α losses in future fusion power plants are expected to follow the co- and counter-current directions due to the isotropy of the fusion reaction. At the ASDEX Upgrade tokamak, the co-current direction (achieved with positive plasma current and negative toroidal magnetic field) has been extensively studied thanks to an array of five fast-ion loss detectors (FILD). A new fast-ion loss detector compatible with reversed Ip/Bt (negative plasma current and positive magnetic toroidal field, defining positive as counter-clockwise when the machine is viewed from the top), namely RFILD, has been designed and commissioned to study the behaviour of counter-current fast-ion losses and to expand our knowledge on QH-mode, I-mode, and the L-H transition. The detector is a modified version of the midplane manipulator fast-ion loss detector that features a new probe head orientation and collimator geometry, optimised using the FILDSIM code. A fast CMOS camera is used as a high spatial resolution acquisition system, while an array of photomultipliers (up to 1 MHz) serves as a fast channel. First measurements have been taken in I-mode, QH-mode, L-mode and H-mode with core densities ranging between 4·1019 and 9·1019 m−3, IP between -0.8 and -0.6 MA and Bt of 2.5 T approximately. NBI fast-ion losses were observed for the first time in reversed Ip/Bt, producing high pitch (60 – 80°) losses. ICRH losses in H-minority heating configuration have also been observed in I-mode experiments. These losses correspond to the outer leg of banana particle trajectories. An upgraded double collimator detector design is also presented, that will increase the measurable particle range in future experimental campaigns (co- and counter-current particles simultaneously). Thus, we expand our understanding on the mechanisms behind fast-ion losses at the ASDEX Upgrade tokamak in the reversed Ip/Bt configuration. |
Agencias financiadoras | Unión Europea (UE). H2020 Unión Europea (UE). Programa de Investigación y Formación Euratom |
Identificador del proyecto | 805162
101052200 |
Cita | Hidalgo Salaverri, J., Rueda Rueda, J., Galdón Quiroga, J., Cano Megías, P., Viezzer, E., García Domínguez, J.,...,Happel, T. (2023). First measurements of a scintillator-based fast-ion loss detector in reversed Ip/Bt at the ASDEX Upgrade tokamak. Fusion Engineering and Design, 193, 113661. https://doi.org/10.1016/j.fusengdes.2023.113661. |
Ficheros | Tamaño | Formato | Ver | Descripción |
---|---|---|---|---|
FED_2023_Hidalgo_First-measure ... | 8.060Mb | [PDF] | Ver/ | |