Buscar
Mostrando ítems 1-4 de 4
Ponencia
Model updating of a historical building by using ambient vibration tests : Chapel of the Würzburg Residence (Germany)
(Víctor Compán Cardiel [etc.], 2015)
One of the first difficulties that can be detected in finite element models of historical buildings is the high level of uncertainty associated with many factors affecting the actual behaviour of the structure. Often the ...
Ponencia
Application of operational modal analysis method in the Monastery of San Jeronimo (Seville, Spain)
(2014)
The use of Operational Modal Analysis is establishing as an acceptable tool for the update of numerical models. Through its application, mechanical properties of structural elements, as stiffness or mass, can be obtained ...
Ponencia
Análisis estructural del monasterio de San Jerónimo de Buenavista. Sevilla
(2014)
El monasterio de San Jerónimo de Buenavista en Sevilla fue construido en 1414. Desde entonces ha sufrido grandes daños, manteniéndose en la actualidad solamente el claustro principal. Este último incluso sufrió daños de ...
Ponencia
Predicción de la estabilidad estructural mediante Análisis Modal Operacional. Teatro Romano de Cádiz
(2013)
El presente artículo expone la caracterización dinámica de un grupo de edificios situados sobre el Teatro Romano de Cádiz a través de pruebas de vibración ambiental. Con los datos obtenidos de estas pruebas se calibraron ...