Buscar
Mostrando ítems 1-6 de 6
Dataset
Dataset and measurements from a current density sensor during experimental testing of dynamic load cycling for a parallel-serpentine design of a proton exchange membrane fuel cell
(2024-01)
Se presenta un conjunto de datos correspondientes a ensayos experimentales de una pila de combustible de intercambio de protones (PEMFC) con un área activa de aproximadamente 50 cm2, canales con diseño serpentín paralelo ...
Artículo
Dataset and mesh of the CFD numerical model for the modelling and simulation of a PEM fuel cell
(Elsevier, 2022)
A CFD mesh corresponding to a Proton Exchange Membrane Fuel Cell (PEMFC) with an active area of 50 cm2, serpentine channels and cross-flow field distribution is presented. The mesh was developed using ANSYS ICEM CFD ...
Dataset
Dataset and mesh of the CFD numerical model for the modelling and simulation of a PEM fuel cell
(2022-02-11)
A CFD mesh corresponding to a Proton Exchange Membrane Fuel Cell (PEMFC) with an active área of 50 cm2, serpentine channels and cross-flow field distribution is presented. The mesh was developed using ANSYS ICEM CFD Hexa ...
Artículo
Experimental dynamic load cycling and current density measurements of different inlet/outlet configurations of a parallel-serpentine PEMFC
(Elsevier, 2023-11)
Proton-exchange membrane fuel cells (PEMFCs) in the transport sector require specific design and durability, and stable and reliable performance under varying cycling loads. In this study, experimental dynamic load cycling ...
Artículo
Experimental and numerical Investigation on the design of a bioinspired PEM fuel cell
(Elsevier, 2022-10-15)
Proton exchange membrane fuel cells (PEMFCs) are promising energy devices that directly convert chemical energy of fuels such as hydrogen to useful work with negligible environmental impact and high efficiency. The channel ...
Artículo
Voltage distribution analysis and non-uniformity assessment in a 100 cm2 PEM fuel cell stack
(Elsevier, 2023-11)
In this study, a comprehensive set of experimental tests were carried out to investigate individual cell voltage and temperature deviation under different operating conditions in a fuel cell stack. Five key operating ...