Buscar
Mostrando ítems 1-8 de 8
Ponencia
A new technique for short-term reliability assessment of transmission and distribution networks
(IEEE Xplore, 2006)
This paper proposes a new methodology for shortterm (24 hours) reliability assessment of transmission and distribution networks, including detailed substations models. Substations are first considered as single electrical ...
Artículo
A Hybrid Procedure Including Subtransmission Systems and Substations for Reliability Assessment
(IEEE Xplore Digital Library, 2013)
A new procedure focused on reliability analysis of subtransmission systems supported by the state enumeration technique is presented. This new methodology is conducted in three stages. First, a classical state enumeration ...
Tesis Doctoral
Ponencia
Metodología para la supervisión de la fiabilidad de las redes de transporte y distribución
(AEDIR (Asociación Española para el Desarrollo de la Ingeniería Electrotécnica), 2005)
En esta comunicación se describe una nueva metodología aplicable al cálculo en tiempo real de los índices de calidad de suministros en redes de transporte y de distribución. Con el método de análisis que se propone, las ...
Artículo
Teaching reliability analysis of HV/MV substations and distribution feeders using educational software
(SAGE, 2012)
In this paper, educational software for the reliability assessment of high/medium-voltage (HV/MV) substations and distribution feeders is presented. It is a useful tool for learning the utility of reliability indices of ...
Ponencia
DCOPF Contingency Analysis Including Phase Shifting Transformers
(Institute of Electrical and Electronics Engineers, 2014)
This work deals with a new formulation for the Direct Current Optimal Power Flow (DCOPF) including the corrective actions related to the phase shifting transformers. The formulation is based on the outage of generators ...
Ponencia
Sensitivity-based external equivalent for reliability assessment of subtransmission & distribution systems
(Curran Associates, Inc., 2011)
It is well known that topology changes in a power system strongly influences the results of reliability assessment studies. Besides, it is obvious that the topology of an external system also affect the reliability of the ...
Artículo
A new DC corrective OPF based on generator and branch outages modelled as fictitious nodal injections
(IEEE Xplore Digital Library, 2014)
This work deals with a new formulation for the direct current corrective optimal power flow. The formulation is based on the outage of generators and/or branches modelled as fictitious injections of active power. By including ...