Buscar
Mostrando ítems 1-8 de 8
Ponencia
Novel dual single sided silicon strip detector chip for radiotherapy verification
(Scuola Internazionale Superiore di Studi Avanzati (S I S S A), 2013)
A novel dual single sided silicon strip detector (SSSSD) chip was designed to meet clinical requirements in radiotherapy verification. An available design from Micron Semiconductor Ltd. (BB7, 500 µ m thick) was the base of ...
Artículo
A new CVD Diamond Mosaic-Detector for (n, α ) Cross-Section Measurements at the n TOF Experiment at CERN
(Elsevier, 2013)
At the n\_TOF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,alpha) cross-section measurements. The detector, characterized by an excellent ...
Artículo
Angular distribution in the neutron-induced fission of actinides
(EDP Sciences, 2013)
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the ...
Ponencia
First experiment: Fragmentation of ions relevant for space and therapy
(IOP Publishing Ltd., 2013)
Nuclear fragmentation processes are relevant in different fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The FIRST (Fragmentation ...
Artículo
Performance of the neutron time-of-flight facility n_TOF at CERN
(Springer Verlag, 2013)
The neutron time-of-flight facility n_TOF features a white neutron source produced by spallation through 20 GeV/c protons impinging on a lead target. The facility, aiming primarily at the measurement of neutron-induced ...
Artículo
Experimental neutron capture data of 58 Ni from the CERN n_TOF facility
(American Physical Society, 2013)
The 58 Ni( n , γ ) cross section has been measured at the neutron time of flight facility n_TOF at CERN, in the energy range from 27 meV up to 400 keV. In total, 51 resonances have been analyzed up to 122 keV. ...
Ponencia
Radia2: A New Tool for Radiotherapy Verification
(AIP Publishing, 2013)
Radiotherapy is nowadays a proven technique in cancer treatments. Within the evolution of radiotherapy treatments towards more complex techniques, the need of new dosimetric methods for treatment verifications has appeared. ...
Ponencia
Neutron Research At The N_TOF Facility (CERN): Results And Perspectives
(American Institute of Physics, 2013)
In the first ten years of operation, the neutron time-of-flight facility n_TOF at CERN has produced a large body of new and accurate data on neutron capture and fission cross sections, relevant to Nuclear Astrophysics and ...