• Ponencia
      Icon

      Characterization of Implanted Stents through Neointimal Tissue Bioimpedance Simulations 

      Portillo Anaya, J.M.; Pérez García, Pablo; Huertas Sánchez, Gloria; Olmo Fernández, Alberto; Serrano, J. A.; Maldonado Jacobi, Andrés; Yúfera García, Alberto (IEEE Computer Society, 2019)
      This work describes how is possible the definition of the light hole or lumen in implanted stents affected by restenosis ...
    • Artículo
      Icon

      Electrical Modeling of the Growth and Differentiation of Skeletal Myoblasts Cell Cultures for Tissue Engineering 

      Olmo Fernández, Alberto; Yuste, Yaiza; Serrano Viseas, Juan Alfonso; Maldonado Jacobi, Andrés; Pérez García, Pablo; Huertas Sánchez, Gloria; Pereira Arenas, Sheila; Yúfera García, Alberto; Portilla de Juan, Fernando de la (MDPI, 2020)
      In tissue engineering, of utmost importance is the control of tissue formation, in order to form tissue constructs of ...
    • Ponencia
      Icon

      Monitoring Tissue Evolution on Electrodes with Bio-Impedance Test 

      Maldonado Jacobi, Andrés; Pérez García, Pablo; Huertas Sánchez, Gloria; Yúfera García, Alberto; Rueda, A.; Huertas, J. L. (IEEE Computer Society, 2016)
      A technique for real-time monitoring of bioimpedances using a Voltage Oscillation (VO) methodology is proposed. The main ...
    • Artículo
      Icon

      Sensing Cell-Culture Assays with Low-Cost Circuitry 

      Pérez García, Pablo; Huertas Sánchez, Gloria; Maldonado Jacobi, Andrés; Martín Rubio, María Esther; Serrano Viseas, Juan Alfonso; Olmo Fernández, Alberto; Daza Navarro, María Paula; Yúfera García, Alberto (Nature Publishing Group, 2018)