Mostrar el registro sencillo del ítem

Ponencia

dc.creatorChang, J. S.es
dc.creatorPontiga Romero, Francisco de Paulaes
dc.creatorAtten, Pierees
dc.creatorCastellanos Mata, Antonioes
dc.date.accessioned2020-07-21T17:08:04Z
dc.date.available2020-07-21T17:08:04Z
dc.date.issued1993
dc.identifier.citationChang, J.S., Pontiga Romero, F.d.P., Atten, P. y Castellanos Mata, A. (1993). Corona discharge characteristics of narrow coaxial wire- pipe discharge tubes with gas flow. En 1993 IEEE Industry Applications Conference, Toronto.
dc.identifier.urihttps://hdl.handle.net/11441/99718
dc.description.abstractAn experimental investigation has been conducted to study corona discharge in a narrow tube. Narrow or capillary corona discharge (dis- charge tube diameter d = 1 to 20 mm) is used for many industrial applications such as flue gas cleaning corona induced plasma reactors, ion sources and electrohydrodynamic heat exchangers. In this work, corona discharge characteristics of narrow coaxial wire-pipe discharge tubes with gas flow are experimentally investigated. The results show that, unlike normal corona discharge, a hysteresis in the corona discharge current-voltage characteristics were observed for narrow tube discharges. The on-set of the corona discharge observed to be significantly depends on the gas temperature and gas flow rates 1.588 cm 0.d. copper tube was placed coaxially outside the system. Entrance and exit gas temperature of the wire-pipe corona discharge zone and outer-grounded pipe gas cooling zone were measured by T-type thermocouples. Time-averaged current was measured by the Keithly electrometer, and air flow rate in both flow channels was measured by a rotameter. The air flow flowing through the corona discharge zone was electrically heated at upstream of the system. Experiments are conducted for the gas flow rate from 0 to 20 [/min., the inlet gas temperature from 10 to 60°C, and the applied voltage from 0 to It 10 kVes
dc.formatapplication/pdfes
dc.format.extent7 p.es
dc.language.isoenges
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCoaxial wire- pipe dischargees
dc.subjectCorona dischargees
dc.titleCorona discharge characteristics of narrow coaxial wire- pipe discharge tubes with gas flowes
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Aplicada IIes
dc.publication.initialPage1887es
dc.publication.endPage1893es
dc.eventtitle1993 IEEE Industry Applications Conferencees
dc.eventinstitutionTorontoes
dc.identifier.sisius21401043es

FicherosTamañoFormatoVerDescripción
2030213030094 (2)-2-8.pdf456.4KbIcon   [PDF] Ver/Abrir   Ponencia

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional