Mostrar el registro sencillo del ítem
Artículo
Autocalibrating quasistatic M‐H hysteresis loop tracer with negligible drift
dc.creator | Franco García, Victorino | es |
dc.creator | Conde Amiano, Alejandro | es |
dc.creator | Ramos Martos, J. | es |
dc.date.accessioned | 2018-05-07T07:43:40Z | |
dc.date.available | 2018-05-07T07:43:40Z | |
dc.date.issued | 1996 | |
dc.identifier.citation | Franco García, V., Conde Amiano, A. y Ramos Martos, J. (1996). Autocalibrating quasistatic M‐H hysteresis loop tracer with negligible drift. Review of Scientific Instruments, 67 (12), 4167-4170. | |
dc.identifier.issn | 0034-6748 | es |
dc.identifier.uri | https://hdl.handle.net/11441/74158 | |
dc.description.abstract | A computer‐controlled system for measuring M‐Hhysteresis loops of soft magnetic materials is described. It overcomes many of the problems associated with these kinds of measurements of low coercivity materials. The combination of ‘‘low drift’’ hardware and measurement procedure makes software correction unnecessary. At every field step, the homemade integrator is reset in order to minimize the drift and to provide a way of separating the sample contribution to the signal from the field contribution and, consequently, to allow M‐H plots. Furthermore, to avoid the residual drift of the hardware, the method of ‘‘two‐way measurement’’ is applied, giving drifts of 0.01% per hour. Results obtained for a FINEMET alloy filmannealed at different temperatures are presented, illustrating the ability of the system to measure soft magnetic materials. | es |
dc.description.sponsorship | Gobierno de España MAT95-961-CO2-01 | es |
dc.format | application/pdf | es |
dc.language.iso | eng | es |
dc.publisher | AIP Publishing | es |
dc.relation.ispartof | Review of Scientific Instruments, 67 (12), 4167-4170. | |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | Autocalibrating quasistatic M‐H hysteresis loop tracer with negligible drift | es |
dc.type | info:eu-repo/semantics/article | es |
dc.type.version | info:eu-repo/semantics/acceptedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física de la Matería Condensada | es |
dc.relation.projectID | MAT95-961-CO2-01 | es |
dc.relation.publisherversion | http://dx.doi.org/10.1063/1.1147563 | es |
dc.identifier.doi | 10.1063/1.1147563 | es |
idus.format.extent | 4 p. | es |
dc.journaltitle | Review of Scientific Instruments | es |
dc.publication.volumen | 67 | es |
dc.publication.issue | 12 | es |
dc.publication.initialPage | 4167 | es |
dc.publication.endPage | 4170 | es |
dc.contributor.funder | Gobierno de España |
Ficheros | Tamaño | Formato | Ver | Descripción |
---|---|---|---|---|
Autocalibrating quasistatic M-H ... | 309.6Kb | [PDF] | Ver/ | |