dc.description.abstract | En los colorímetros que existen en el mercado, la luz se
recoge mediante un tubo de cierto diámetro y los valores
de las coordenadas cromáticas que da el medidor son
una media de las obtenidas en dicha superficie. Cuando
la superficie a medir no tiene un color uniforme, como
ocurre en el caso de los materiales pétreos, la medida de
color es más representativa cuanto mayor es la apertura
del tubo de medida ya que la superficie medida es mayor.
Este hecho, que en ocasiones supone una ventaja, presenta
el inconveniente de que cuando la superficie objeto
de estudio es inferior a la apertura del tubo de proyección
del colorímetro utilizado, los valores obtenidos integran
zonas no deseadas.
Una posible solución a este inconveniente es la utilización
de plantillas que reduzcan el área de medida. En este trabajo
se ensayan plantillas adaptadoras del tubo de medida
de un colorímetro Minolta CR-210, y se llega a la conclusión
de que su uso, además de fácil, permite obtener
el color original de la superficie medida, es decir, el valor
que tendría si no se hubieran utilizado las plantillas. | es |
dc.description.abstract | The colour coordinate values measured with the colorimeters
presently on the market are the mean of the readings
obtained for the surface area covered by the light projection
tube. When the colour of the surface measured is not
uniform, such as in the case of stone, the larger the tube
aperture the more representative is the colour measurement,
for a larger area is involved. While this is often an
advantage, when the area studied is smaller than the
aperture of the colorimeter used, the values obtained
include unwanted information.
One possible way to deal with this drawback is by using
templates to reduce the measurement area. Templates
adapted to a Minolta CR-210 colorimeter were tested in the
present study. The conclusion drawn was that in addition
to being convenient to use, they ensured that the readings
matched the original colour of the surface, i.e., the value
that would have been obtained without the templates. | eng |
dc.language.iso | eng | spa |
dc.language.iso | spa | spa |
dc.relation.ispartof | Materiales de construcción, 58(291), 99-109 | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Colorimetría | es |
dc.subject | Plantillas | eng |
dc.subject | Coordenadas cromáticas | es |
dc.subject | Adaptadores | es |
dc.subject | Colorimetry | en |
dc.subject | Templates | en |
dc.subject | Colorimetric coordinates | en |
dc.subject | Adapters | en |
dc.title | Influencia del diámetro y color de plantillas reductoras de la superficie de proyección de los colorímetros en la medida del color de una superficie | es |
dc.type | info:eu-repo/semantics/article | |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
dc.identifier.idus | https://idus.us.es/xmlui/handle/11441/17645 | |