Article
Construcción y monitorización del Laboratorio REVen para el estudio del impacto de las ventanas integrando eficiencia energética y calidad ambiental interior
Alternative title | Construction and monitoring of the REVen Laboratory for the study of the impact of windows on energy efficiency and Indoor Environmental Quality |
Author/s | Arranz Arranz, Beatriz
Oteiza San José, Ignacio de Delgado Gutiérrez, Evelyn Yaneth Gutiérrez Martín, Álvaro |
Department | Universidad de Sevilla. Departamento de Construcciones Arquitectónicas II (ETSIE) |
Publication Date | 2020 |
Deposit Date | 2024-01-31 |
Published in |
|
Abstract | El proyecto REVen “Rehabilitación energética de viviendas sociales, aplicando productos innovadores de ventana con marcado CE” (BIA2014-56650-JIN), tiene como objetivo realizar un análisis integral del impacto de la ventana ... El proyecto REVen “Rehabilitación energética de viviendas sociales, aplicando productos innovadores de ventana con marcado CE” (BIA2014-56650-JIN), tiene como objetivo realizar un análisis integral del impacto de la ventana en los aspectos relativos a eficiencia energética y calidad ambiental. Para caracterizar los flujos de energía y las condiciones ambientales internas se ha construido el Laboratorio REVen. Este artículo describe la construcción y la monitorización de este laboratorio analizando los datos de su primer año de funcionamiento. Los resultados permiten afirmar que se logra una mejora significativa del confort térmico obteniendo un ahorro de energía anual del 25 %. REVen Project: “Energy retrofitting of social housing, using innovative window products satisfying CE marking requirements”. (BIA2014-56650-JIN) aims to carry out a comprehensive analysis of window impact on aspects related ... REVen Project: “Energy retrofitting of social housing, using innovative window products satisfying CE marking requirements”. (BIA2014-56650-JIN) aims to carry out a comprehensive analysis of window impact on aspects related to energy efficiency and indoor environmental quality. REVen Laboratory has been built to characterize the energy flows and internal environmental conditions. This article describes the construction and monitoring of this laboratory analyzing the data of its first year of operation. Results can affirm that in the conditions of the test, a significant improvement on thermal comfort is observed obtaining an annual energy saving of 25%. |
Funding agencies | Ministerio de Economia, Industria y Competitividad (MINECO). España European Commission (EC). Fondo Europeo de Desarrollo Regional (FEDER) |
Project ID. | BIA2014-56650-JIN |
Citation | Arranz Arranz, B., Oteiza San José, I.d., Delgado Gutiérrez, E.Y. y Gutiérrez Martín, Á. (2020). Construcción y monitorización del Laboratorio REVen para el estudio del impacto de las ventanas integrando eficiencia energética y calidad ambiental interior. Informes de la construcción, 72(557) (e324). https://doi.org/10.3989/ic.67523. |
Files | Size | Format | View | Description |
---|---|---|---|---|
Construcción y monitorización ... | 4.879Mb | [PDF] | View/ | |