Mostrar el registro sencillo del ítem

Artículo

dc.creatorVera Medina, Jonathanes
dc.creatorLillo Bravo, Isidoroes
dc.creatorHernández, J.es
dc.creatorLarrañeta, Migueles
dc.date.accessioned2024-01-04T11:40:38Z
dc.date.available2024-01-04T11:40:38Z
dc.date.issued2018-05
dc.identifier.citationVera-Medina, J., Lillo-Bravo, I., Hernández, J. y Larrañeta, M. (2018). Experimental and numerical study on a freeze protection system for flat-plate solar collectors with silicone peroxide tubes. Applied Thermal Engineering, 135, 446-453. https://doi.org/10.1016/j.applthermaleng.2018.02.085.
dc.identifier.issn1359-4311es
dc.identifier.issn1873-5606es
dc.identifier.urihttps://hdl.handle.net/11441/152956
dc.description.abstractThe freeze protection is essential in the majority of solar thermal installations to prevent breakage of solar thermal collectors. Therefore, there are different methods of protection against freezing of flat plate solar thermal collectors, all of them with certain limitations. This paper shows a novel freeze protection mechanism in the solar thermal collector by using flexible silicone peroxide tubes inside the absorber of the solar collector. We demonstrate, in a theoretical and experimental way, that the increase of volume and pressure produced inside a solar collector during freezing process can be absorbed using a flexible silicone peroxide tubes under all exposure conditions. The parameters that optimize the geometric configuration of the solution proposed have been calculated. A collector prototype with silicones peroxide has experimentally complied with the Standard ISO 9806:20 13, including freeze resistance test, without any significantly influence on its efficiency or pressure drop. Therefore, the solution proposed presents an inexpensive, effective, reliable and maintenance-free freeze protection system for flat plate solar collectors.es
dc.formatapplication/pdfes
dc.format.extent8 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofApplied Thermal Engineering, 135, 446-453.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectSolar collectores
dc.subjectFreeze protectiones
dc.subjectSilicone peroxidees
dc.titleExperimental and numerical study on a freeze protection system for flat-plate solar collectors with silicone peroxide tubeses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Energéticaes
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S1359431117314886es
dc.identifier.doi10.1016/j.applthermaleng.2018.02.085es
dc.contributor.groupUniversidad de Sevilla. TEP122: Termodinámica y Energías Renovableses
dc.journaltitleApplied Thermal Engineeringes
dc.publication.volumen135es
dc.publication.initialPage446es
dc.publication.endPage453es

FicherosTamañoFormatoVerDescripción
ATE_2018_Lillo-Bravo_Larraneta ...1.110MbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional