Mostrar el registro sencillo del ítem

Artículo

dc.creatorTávara Vidalón, Priscilaes
dc.creatorLafuente Sotillos, Guillermoes
dc.creatorMunuera Martínez, Pedro Vicentees
dc.date.accessioned2023-11-23T12:02:49Z
dc.date.available2023-11-23T12:02:49Z
dc.date.issued2021
dc.identifier.citationTávara Vidalón, P., Lafuente Sotillos, G. y Munuera Martínez, P.V. (2021). Movimiento del primer radio en sujetos con hallux limitus vs. sujetos con pies normales. Revista Española de Podología, 32 (2), 116-122. https://doi.org/10.20986/revesppod.2021.1621/2021.
dc.identifier.issn0210-1238es
dc.identifier.urihttps://hdl.handle.net/11441/151426
dc.description.abstractObjetivos: El objetivo de este trabajo fue determinar el movimiento del primer radio en el plano sagital en sujetos con hallux limitus y compararlo con el de los sujetos con pies normales mediante el uso de un nuevo instrumento de medida del primer radio. Además, valorar la relación entre la extensión metatarsofalángica y los movimientos del primer radio. Pacientes y métodos: Se valoró la extensión de la primera articulación metatarsofalángica y la movilidad del primer radio en el plano sagital en dos grupos de estudio: sujetos con hallux limitus y un grupo control. Para ello se utilizó un nuevo instrumento de medida del primer radio válido y fiable. Resultados: El movimiento del primer radio para el grupo de hallux limitus en el plano sagital fue de 7.04 ± 0.22 mm de dorsiflexión, 3.51 ± 0.29 mm de plantarflexión y de 10.55 ± 0.33 mm de rango total. Y para el grupo control fue de 5.82 ± 0.21 mm de dorsiflexión, 5.33 ± 0.21 mm de plantarflexión y de 11.15 ± 0.39 mm de rango total. El movimiento total de extensión metatarsofalángica mostró una correlación moderada y directa con la plantarflexión del primer radio (r = 0.63), y débil e inversa con la dorsiflexión del primer radio (r = - 0.36). Conclusión: En los participantes de este estudio se observó que los sujetos con hallux limitus presentaron más movimiento en dorsiflexión y menos movimiento en plantarflexión que los sujetos normales. Sin embargo, el rango de movimiento total fue similar para ambos grupos de estudio.es
dc.description.abstractObjectives: The objective of this study was to determine the first ray range of motion (ROM) in the sagittal plane in hallux limitus patients and to compare it with those patients with normal feet by using a new measuring device of first ray mobility. In addition, to assess the relationship between metatarsophalangeal dorsiflexion and first ray mobility. Patients and methods: The dorsiflexion for the first metatarsophalangeal joint and the mobility of the first ray in the sagittal plane were assessed in two study groups: hallux limitus patients and a control group. A new valid and reliable measuring device of the first ray mobility was used. Results: ROM of the first ray for the hallux limitus group in the sagittal plane was 7.04 ± 0.22 mm for dorsiflexion, 3.51 ± 0.29 mm for plantarflexion, and 10.55 ± 0.33 mm of total range. And for the control group it was 5.82 ± 0.21 mm of dorsiflexion, 5.33 ± 0.21 mm of plantarflexion and 11.15 ± 0.39 mm of total range. The total movement of metatarsophalangeal dorsiflexion showed a moderate and direct correlation with the plantarflexion of the first ray (r = 0.63), and weak and inverse with the dorsiflexion of the first ray (r = - 0.36). Conclusion: In the participants of this study, it was observed that the subjects with hallux limitus had more dorsiflexion and less plantarflexion than normal subjects. However the total range of motion was similar in both study groups.es
dc.formatapplication/pdfes
dc.format.extent7es
dc.language.isospaes
dc.language.isoenges
dc.publisherConsejo General de Colegios Oficiales de Podólogoses
dc.relation.ispartofRevista Española de Podología, 32 (2), 116-122.
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectHallux limituses
dc.subjectHallux rigiduses
dc.subjectPrimer radioes
dc.subjectDorsiflexiónes
dc.subjectPlantarflexiónes
dc.subjectInstrumento de medidaes
dc.subjectFirst rayes
dc.subjectDorsiflexiones
dc.subjectPlantarflexiones
dc.subjectMeasurement devicees
dc.titleMovimiento del primer radio en sujetos con hallux limitus vs. sujetos con pies normaleses
dc.title.alternativeFirst ray mobility in hallux limitus patients vs. normal patientses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Podologíaes
dc.identifier.doi10.20986/revesppod.2021.1621/2021es
dc.contributor.groupUniversidad de Sevilla. CTS-601: Hermeses
dc.journaltitleRevista Española de Podologíaes
dc.publication.volumen32es
dc.publication.issue2es
dc.publication.initialPage116es
dc.publication.endPage122es

FicherosTamañoFormatoVerDescripción
Movimiento del pimer radio.pdf1.717MbIcon   [PDF] Ver/Abrir  
First ray mobility in hallux ...1.637MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución 4.0 Internacional