Article
Application of Diamond Detectors in Tracking of Heavy Ion Slowed Down Radioactive Beams
Author/s | Bednarczyk, P.
Berdermann, E. Gerl, J. Górska, M. Kojouharov, I. Pomorski, M. González Álvarez, Marcos Aurelio Espino Navas, José Manuel Wolski, R. |
Department | Universidad de Sevilla. Departamento de Física Atómica, Molecular y Nuclear |
Publication Date | 2007 |
Deposit Date | 2022-02-22 |
Published in |
|
Abstract | Results of irradiation of thin Chemical Vapor Deposition (CVD) diamond detectors with low energy: p,α and 7Li beams are presented. Energy resolution: ΔE/E<1% of a single crystal detector was achieved. A coincident measurement ... Results of irradiation of thin Chemical Vapor Deposition (CVD) diamond detectors with low energy: p,α and 7Li beams are presented. Energy resolution: ΔE/E<1% of a single crystal detector was achieved. A coincident measurement with two diamond detectors showed time resolution of 100 ps and efficiency above 70%. Despite a high beam flux reaching 109 particles/s cm2 the tested detectors showed low dead-time and satisfactory radiation hardness. Perspectives of applying thin CVD diamond detectors in monitoring of a slowed down radioactive beam (RIB) are discussed. |
Funding agencies | Ministerio de Educación y Ciencia (MEC). España |
Project ID. | FFPA2003-05958
PA-2005-04460 |
Citation | Bednarczyk, P., Berdermann, E., Gerl, J., Górska, M., Kojouharov, I., Pomorski, M.,...,Wolski, R. (2007). Application of Diamond Detectors in Tracking of Heavy Ion Slowed Down Radioactive Beams. Acta Physica Polonica B, 38 (4), 1293-1296. |
Files | Size | Format | View | Description |
---|---|---|---|---|
v38p1293.pdf | 123.8Kb | [PDF] | View/ | |