Buscar
Mostrando ítems 11-20 de 39
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
80Se(n,?) cross-section measurement at CERN n TOF
(Institute of Physics Publishing, 2020)
Radiative neutron capture cross section measurements are of fundamental importance for the study of the slow neutron capture (s-) process of nucleosynthesis. This mechanism is responsible for the formation of most elements ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
New reaction rates for the destruction of 7Be during big bang nucleosynthesis measured at CERN/n_TOF and their implications on the cosmological lithium problem
(EDP Sciences, 2020)
New measurements of the 7Be(n,α)4He and 7Be(n,p)7Li reaction cross sections from thermal to keV neutron energies have been recently performed at CERN/n_TOF. Based on the new experimental results, astrophysical reaction ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Neutron capture cross section measurement of 151 Sm at the CERN neutron time of flight facility (n_TOF)
(American Physical Society, 2004-10-15)
The151Sm(n,γ)152Sm cross section has been measured at the spallation neutron facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The new facility combines excellent resolution in neutron time-of-flight, low ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Measurement of the 70Ge(n,γ) cross section up to 300 keV at the CERN n_TOF facility
(American Physical Society, 2019)
Neutron capture data on intermediate mass nuclei are of key importance to nucleosynthesis in the weak component of the slow neutron capture processes, which occurs in massive stars. The (n,γ) cross section on 70Ge, which ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Measurement of the neutron capture cross section of the fissile isotope 235U with the CERN n-TOF total absorption calorimeter and a fission tagging based on micromegas detectors
(EDP Sciences, 2017)
The accuracy on neutron capture cross section of fissile isotopes must be improved for the design of future nuclear systems such as Gen-IV reactors and Accelerator Driven Systems. The High Priority Request List of the ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Measurement and analysis of the 241Am(n,γ ) cross section with liquid scintillator detectors using time-of-flight spectroscopy at the n_TOF facility at CERN
(American Physical Society, 2014)
The 241Am(n,γ ) cross section has been measured at the n_TOF facility at CERN using deuterated benzene liquid scintillators, commonly known as C6D6 detectors, and time-of-flight spectrometry. The results in the ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Measurement of the U 238 (n,γ) cross section up to 80 keV with the total absorption calorimeter at the CERN n-TOF facility
(American Physical Society, 2017)
The radiative capture cross section of a highly pure (99.999%), 6.125(2) grams and 9.56(5)× 10−4 atoms/barn areal density 238U sample has been measured with the Total Absorption Calorimeter (TAC) in the 185 m flight path ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Measurement of the energy-differential cross-section of the 12C(n,p)12B and 12C(n,d)11B reactions at the n_TOF facility at CERN
(EDP Sciences, 2020)
Although the 12C(n,p)12B and 12C(n,d)11B reactions are of interest in several fields of basic and applied Nuclear Physics the present knowledge of these two cross-sections is far from being accurate and reliable, with both ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Status and perspectives of the neutron time-of-flight facility n_TOF at CERN
(EDP Sciences, 2020)
Since the start of its operation in 2001, based on an idea of Prof. Carlo Rubbia [1], the neutron time of-flight facility of CERN, n_TOF, has become one of the most forefront neutron facilities in the world for wide-energy ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Setup for the measurement of the 235U(n, f) cross section relative to n-p scattering up to 1 GeV
(EDP Sciences, 2020)
The neutron induced fission of 235U is extensively used as a reference for neutron fluence measurements in various applications, ranging from the investigation of the biological effectiveness of high energy neutrons, to ...