Mostrar el registro sencillo del ítem

Artículo

dc.creatorHesami, Mortezaes
dc.creatorBakhshi, Alies
dc.creatorMousavi, Sheydaes
dc.creatorRouzbehi, Kumarses
dc.creatorEscaño González, Juan Manueles
dc.date.accessioned2021-05-04T15:00:08Z
dc.date.available2021-05-04T15:00:08Z
dc.date.issued2021-03
dc.identifier.citationHesami, M., Bakhshi, A., Mousavi, S., Rouzbehi, K. y Escaño González, J.M. (2021). HVDC Breaker Power Loss Reduction by Bridge-Type Hybrid Breakers. Energies, 14 (6). Article number 1526.
dc.identifier.issnEISSN 1996-1073es
dc.identifier.urihttps://hdl.handle.net/11441/108455
dc.description.abstractSeveral types of high voltage direct current (HVDC) breakers have been introduced and commercialized. Each of them has advantages and disadvantages. Among them, the hybrid HVDC breaker is highly successful. One of the most important concerns that the hybrid HVDC breaker has faced is high power loss throughout its fault current breaking process. The hybrid HVDC breaker comprises a high voltage bidirectional main HVDC breaker. A significant number of electronic switches need to be connected in a series where anti-parallel diodes are essentially embraced. During fault inception, a number of series solid-state switches and a number of series diodes dramatically increase the power loss of the main breaker. This study, firstly, studies the power loss of the hybrid HVDC breaker and later develops a structure of a full-bridge hybrid breaker (FBHB) to reduce the losses of the current structure both in the normal and fault protection states. In this paper simulations are done based on PSCAD. In addition to the analytical study and simulations, we show that the developed structure substantially decreases the amount of power lost during the normal operation and fault current breaking stage.es
dc.formatapplication/pdfes
dc.format.extent12 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofEnergies, 14 (6). Article number 1526.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectHVDC breakeres
dc.subjectPower losses
dc.subjectABB hybrid HVDC breakeres
dc.titleHVDC Breaker Power Loss Reduction by Bridge-Type Hybrid Breakerses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería de Sistemas y Automáticaes
dc.relation.publisherversionhttps://doi.org/10.3390/en14061526es
dc.identifier.doi10.3390/en14061526es
dc.journaltitleEnergieses
dc.publication.volumen14es
dc.publication.issue6es
dc.publication.initialPageArticle number 1526es

FicherosTamañoFormatoVerDescripción
HVDC Breaker Power Loss Reduction ...2.370MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional